1988
DOI: 10.1111/j.1751-908x.1988.tb00041.x
|View full text |Cite
|
Sign up to set email alerts
|

Analyse des Standards de L'U.S.G.S. : GXR‐1 a GXR‐6 par Activation Neutronique et Fluorescence X

Abstract: Six roches standards de I'USGS : GXR‐1 à GXR‐6 ont été analysées par activation neutronique instrumentale (INAA) pour le dosage de 17 éléments traces et par fluorescence X (XRF) pour les autres éléments difficiles à doser par activation neutronique. Les travaux précédemment publiés par Gladney et al. ont été pris comme référence en particulier les valeurs recommandées (R.V.) qui sont généralement en bon accord avec nos résultats. Quelques remarques et corrections sont proposées pour expliquer certaines dispari… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

1
2
0

Year Published

1990
1990
1993
1993

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 3 publications
1
2
0
Order By: Relevance
“…All results by this method fall within the standard deviations given for consensus values. Results for Zr in the GXR series agree with those obtained using XRF by Meyer et al (19) with the exception of the jasperoid GXR-1 where this value of 28 ppm is closer t3 that of Watkins arid Thompson (1 2), 30 pprn by ICP-ES and LBO2 fusion. 'The lack of agreement for Zr in MESS-1 and BCSS-1 is not cause for concern as the concentrations cited are semi-quantitative only and intended as guideline information.…”
Section: Resultssupporting
confidence: 84%
See 2 more Smart Citations
“…All results by this method fall within the standard deviations given for consensus values. Results for Zr in the GXR series agree with those obtained using XRF by Meyer et al (19) with the exception of the jasperoid GXR-1 where this value of 28 ppm is closer t3 that of Watkins arid Thompson (1 2), 30 pprn by ICP-ES and LBO2 fusion. 'The lack of agreement for Zr in MESS-1 and BCSS-1 is not cause for concern as the concentrations cited are semi-quantitative only and intended as guideline information.…”
Section: Resultssupporting
confidence: 84%
“…The results of the application of the proposed method to the determination of Zr, Nb, H f and Ta in 74 geological SRMs are shown in Tables 1 and 2. The literature values given for comparison purposes are derived from compilation reports (6,(16)(17)(18)20,23,25,27), certificate information (21.22) and individual methods (1,19,26,28). Values which are underlined are 'recommended' as distinguished from 'proposed' and are taken from the recent major international compilation by Govindaraju (16).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation