Análise de suspensões de argilas por espectrometria de emissão óptica com plasma induzido com configuração axial

Abstract: Recebido em 23/1/02; aceito em 17/4/02 CLAY SLURRIES ANALYSIS USING INDUCTIVELY COUPLED PLASMA OPTICAL EMISSION SPECTROMETRY WITH AXIAL VIEW CONFIGURATION. The goal of this study was to evaluate the feasibility of direct introduction of clay slurries in an inductively coupled plasma optical emission spectrometer with axial view configuration. Calibration was performed using a certified reference material with a mean particle size of 13 µm (IPT-42) and the analytical curve was applied for quantification of two … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0
2

Year Published

2004
2004
2019
2019

Publication Types

Select...
8
1

Relationship

4
5

Authors

Journals

citations
Cited by 10 publications
(8 citation statements)
references
References 7 publications
0
6
0
2
Order By: Relevance
“…The ideal particle size is dependent on the type of sample introduction system used, on the thermochemical behavior of particles and on the properties of the plasma. 26 However, cement slurries 27,30 with particle sizes lower than 38 µm were accurately analysed using an axially viewed ICP OES. Babington or V-groove nebulizers are suitable for slurry nebulization in order to avoid clogging.…”
Section: Use Of Icp Oes With Axially Viewed Configuration For Analysimentioning
confidence: 99%
See 1 more Smart Citation
“…The ideal particle size is dependent on the type of sample introduction system used, on the thermochemical behavior of particles and on the properties of the plasma. 26 However, cement slurries 27,30 with particle sizes lower than 38 µm were accurately analysed using an axially viewed ICP OES. Babington or V-groove nebulizers are suitable for slurry nebulization in order to avoid clogging.…”
Section: Use Of Icp Oes With Axially Viewed Configuration For Analysimentioning
confidence: 99%
“…Additionally, residence times could also be altered. Some publications proposed the use of increasing masses of certified reference materials for the calibration, [25][26][27] but aqueous solutions could also be used. 27,[31][32][33] The use of the generalized standard additions method (GSAM), an expansion of the conventional standard additions method, has also been proposed for slurry analysis in a dual view 28 and in an axially viewed ICP OES.…”
Section: Use Of Icp Oes With Axially Viewed Configuration For Analysimentioning
confidence: 99%
“…This procedure was based on a procedure developed by Silva et al for analysis of clays. 12 Chemical modification effects were evaluated by changes in the emission intensities of Al, Ca, Fe, K, Mg, P, Si, and Ti measured in an ICP OES with axial viewing.…”
Section: Methodsmentioning
confidence: 99%
“…Segundo Silva et al 2 uma das dificuldades é a obtenção de informações sobre os materiais de referên-cia certificados e as amostras que geralmente não estão disponíveis e não podem ser obtidas rapidamente. Essas informações são necessá-rias para facilitar a calibração do espectrômetro ICP OES 2 .…”
Section: Introductionunclassified