2015
DOI: 10.1016/j.bios.2015.05.012
|View full text |Cite
|
Sign up to set email alerts
|

An ultrasensitive squamous cell carcinoma antigen biosensing platform utilizing double-antibody single-channel amplification strategy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
12
1

Year Published

2016
2016
2022
2022

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 27 publications
(13 citation statements)
references
References 18 publications
0
12
1
Order By: Relevance
“…And the detection limit was estimated to be 0.25 pg·mL −1 (S/N = 3). The detection limit was lower than those in some previous reports 2 26 27 28 29 , such as 2.8 pg·mL −1 , 0.02 ng·mL −1 , 1.0 pg·mL −1 , 8.53 pg·mL −1 and 0.17 ng·mL −1 . The results indicated enough sensitivity for monitoring SCCA.…”
Section: Resultscontrasting
confidence: 66%
See 1 more Smart Citation
“…And the detection limit was estimated to be 0.25 pg·mL −1 (S/N = 3). The detection limit was lower than those in some previous reports 2 26 27 28 29 , such as 2.8 pg·mL −1 , 0.02 ng·mL −1 , 1.0 pg·mL −1 , 8.53 pg·mL −1 and 0.17 ng·mL −1 . The results indicated enough sensitivity for monitoring SCCA.…”
Section: Resultscontrasting
confidence: 66%
“…Squamous cell carcinoma antigen (SCCA), as a member of the serine protease inhibitors family, is often used as a tumour marker with squamous cell carcinoma 1 2 . The SCCA normally exists in basal and parabasal layers of normal squamous epithelium with a low level, but it is found to be overexpressed in epithelia of cancerous tissue 3 .…”
mentioning
confidence: 99%
“…Another method is based on the functionalization of the MeNPs with bifunctional linkers (carboxyl-thiols, amine-thiols) or adapter molecules (streptavidin, biotin) and making them react with the Ab via EDC/NHS chemistry (Figure 2c) [16,19]. Several works employing Au, Pt, Pd, Cu, Ag nanoparticles as electrode materials are found in the literature [20][21][22][23][24][25][26][27][28][29]. However, despite their numerous features, MeNPs are not suitable for sufficient signal amplification by themselves [30].…”
Section: Metallic Nanoparticlesmentioning
confidence: 99%
“…The effect of these foreign species under optimized CL conditions was determined by analyzing the standard solution of zolpidem (61.4 ng mL -1 ) in presence of these compounds. The tolerance of each substance was taken as the largest concentration of substance yielding an error of less than 3σ in the analytical signal of 61.4 ng mL -1 of zolpidem (σ is the standard deviation in the response obtained from 11 times repeating determination of 61.4 ng mL -1 zolpidem) [32]. The results showed that no interference could be detected when the sample include up to a 100 fold Al 3+ , Fe 2+ , K + , Ca 2+ , Mg 2+ Na + , NO3 -, Starch, 10 folds of sucrose, and uric acid.…”
Section: Interference Studymentioning
confidence: 99%
“…CL methods have found extensive applications in many interesting areas, but their main disadvantages are usually related, in general, with their poor selectivity [25]. Some ultrasensitive methods also have potential for determining the target molecules [28][29][30][31][32][33][34].…”
Section: Introductionmentioning
confidence: 99%