2018
DOI: 10.1016/j.rser.2017.09.055
|View full text |Cite
|
Sign up to set email alerts
|

An overview on prospects of new generation single-phase transformerless inverters for grid-connected photovoltaic (PV) systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
30
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 45 publications
(30 citation statements)
references
References 46 publications
0
30
0
Order By: Relevance
“…(vii) xf(pu)≤0.1pu in order to limit the AC voltage drop during operation, thus enhancing the dynamic response of the PV inverter [30]. (viii) the switching frequency is usually in the range for both converters composing the PVC [29]; it is used for the estimation of the range of coefficients, k 3 -k 11 with (A4), (A9) and (A10). The maximum value of the switching frequency is also limited by additional constraints on coefficients and mentioned below.…”
Section: B Determination Of Coefficients Following Technical Constramentioning
confidence: 99%
“…(vii) xf(pu)≤0.1pu in order to limit the AC voltage drop during operation, thus enhancing the dynamic response of the PV inverter [30]. (viii) the switching frequency is usually in the range for both converters composing the PVC [29]; it is used for the estimation of the range of coefficients, k 3 -k 11 with (A4), (A9) and (A10). The maximum value of the switching frequency is also limited by additional constraints on coefficients and mentioned below.…”
Section: B Determination Of Coefficients Following Technical Constramentioning
confidence: 99%
“…Electronics 2019, 8, x FOR PEER REVIEW 2 of 9 [13][14][15][16]. Moreover, also the inverter efficiency typically depends on the delivered power level [17][18][19]. This work aims at demonstrating the importance of taking into account the dependence of the efficiency on the output power of batteries and inverters when defining management strategies for battery-based storage systems interfaced with the distribution grid.…”
Section: Fundamentals Of Proposed Management Strategymentioning
confidence: 99%
“…In both the plots of Figures 1 and 2, the efficiency is reported as a function of the output power normalized with respect to the maximum output. The curve of Figure 1 was constructed by considering typical efficiency profiles of commercial inverters, in which the efficiency usually degrades at low output power levels because of switching and conducting power losses in the circuit elements of the inverter [17][18][19]. The curve of Figure 1 was constructed by considering typical efficiency profiles of commercial inverters, in which the efficiency usually degrades at low output power levels because of switching and conducting power losses in the circuit elements of the inverter [17][18][19].…”
Section: Fundamentals Of Proposed Management Strategymentioning
confidence: 99%
See 2 more Smart Citations