“…In Reference 71, a mixed‐integer program model is proposed to find the island boundaries of controlled islanding. The objective function defined in Reference 70 is used to minimize load shedding.…”
Section: Sips Applicationsmentioning
confidence: 99%
“…In Reference 71, a mixed‐integer program model is proposed to find the island boundaries of controlled islanding. The objective function defined in Reference 70 is used to minimize load shedding.…”
Section: Sips Applicationsmentioning
confidence: 99%
“…In this respect, it has been shown in the existing literature that coordination between ICI and other SIPSs, such as UFLS, needs to be researched [10]. Namely, it turned out Energies 2021, 14, 2790 2 of 13 that an UFLS scheme operating by means of frequency and rate-of-change-of-frequency (RoCoF) relay tripping is not always able to avoid frequency instability.…”
Section: Introductionmentioning
confidence: 99%
“…To the best of the authors' knowledge, only a few research papers considered a power plant outage as an initial event, which is probably due to the fact that it was detected as an initiating event in only 11% of the cases [20]. In the course of EPS deterioration, generator tripping was indeed one of the consequences, but the operational issues began with a short-circuit fault [10,21].…”
Section: Introductionmentioning
confidence: 99%
“…The ICI algorithms proposed in References 34,35, which employ DC and AC power flow constraints, respectively, try to improve the frequency stability of resulted islands with different constraints. In Reference 36, the method of Reference 35 has been extended by considering under frequency load shedding (UFLS) relays. However, these approaches have not considered the response time of different corrective actions, which may make them inapplicable to real‐world power systems.…”
Section: Introductionmentioning
confidence: 99%
“…While some previous ICI works (such as References 19,23,28) have focused on minimal power flow disruption, some other ones (such as References 20,35,36) have considered minimal power imbalance as the objective to obtain optimal islanding strategies. However, as the first contribution of this article, the proposed ICI approach jointly minimizes both the power imbalance and the power flow disruption to obtain more effective islanding solutions benefiting from the advantages of the both groups.…”
Section: Introductionmentioning