2012
DOI: 10.1016/j.talanta.2012.03.061
|View full text |Cite
|
Sign up to set email alerts
|

An integrated lab-on-a-disc for automated cell-based allergen screening bioassays

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0

Year Published

2013
2013
2019
2019

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(11 citation statements)
references
References 21 publications
0
11
0
Order By: Relevance
“…The drug screening to suppress the fMLP-mediated degranulation in basophils was recently  -Fluid viscosity Q -Vol. flow rate w -Channel width h -Channel height 2 6 wh Q    examined using an integrated centrifugal microfluidic platform (Kwok et al 2016, Chen et al 2012. Furthermore, a chip-cytometry technique has been used for quantification of bead-based purified basophils from bronchoalveolar lavage (BAL) and blood in asthmatic patients (Dijkstra et al 2014).…”
Section: Microfluidic Based Basophil Functional Analysismentioning
confidence: 99%
“…The drug screening to suppress the fMLP-mediated degranulation in basophils was recently  -Fluid viscosity Q -Vol. flow rate w -Channel width h -Channel height 2 6 wh Q    examined using an integrated centrifugal microfluidic platform (Kwok et al 2016, Chen et al 2012. Furthermore, a chip-cytometry technique has been used for quantification of bead-based purified basophils from bronchoalveolar lavage (BAL) and blood in asthmatic patients (Dijkstra et al 2014).…”
Section: Microfluidic Based Basophil Functional Analysismentioning
confidence: 99%
“…Nwankire et al, 2013). LoaD platforms have also been developed for cell handling, bioassays (Boettcher et al, 2006;Burger and Ducrée, 2012;Chen et al, 2012;Lee et al, 2014a) and have also been interfaced with electrical systems for real-time flow monitoring (Abi-Samra et al, 2013). For cell detection, electrochemical schemes are beneficial due to their ability to provide highly sensitive, rapid real-time quantitative information, based on simple instrumentation.…”
Section: Introductionmentioning
confidence: 99%
“…Flow control is achieved by varying the spinning speed, spinning direction, and operations such as valve opening, siphoning, volume metering, mixing, and flow switching. In our previous studies, a LOAD platform was built for allergy testing [ 16 , 17 ]. In our second generation LOAD, the AO-loaded cells that were sensitized with a patient’s serum or medium alone were challenged with suspected allergens or other triggers in chamber at body temperature (37 °C).…”
Section: Introductionmentioning
confidence: 99%