2011
DOI: 10.1007/s10439-011-0330-5
|View full text |Cite
|
Sign up to set email alerts
|

An Integrated Framework to Quantitatively Link Mouse-Specific Hemodynamics to Aneurysm Formation in Angiotensin II-infused ApoE −/− mice

Abstract: Locally disturbed flow has been suggested to play a (modulating) role in abdominal aortic aneurysm (AAA) formation, but no longitudinal studies have been performed yet due to (a.o.) a lack of human data prior to AAA formation. In this study we made use of recent advances in small animal imaging technology in order to set up entirely mouse-specific computational fluid dynamics (CFD) simulations of the abdominal aorta in an established ApoE -/- mouse model of AAA formation, combining (i) in vivo contrast-enhance… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

3
50
1
1

Year Published

2011
2011
2023
2023

Publication Types

Select...
5
2

Relationship

3
4

Authors

Journals

citations
Cited by 44 publications
(55 citation statements)
references
References 36 publications
3
50
1
1
Order By: Relevance
“…Many authors have tried to link local disease patterns to focal zones of locally disturbed shear stress using rigid-walled models of either the aortic arch (Assemat et al, 2014;Feintuch et al, 2007;Suo et al, 2007;Yap et al, 2014), the abdominal aorta (Ford et al, 2011;Greve et al, 2006;Trachet et al, 2011b;Willett et al, 2010) or both (Hoi et al, 2011;Huo et al, 2008;Van Doormaal et al, 2014). The findings of publications that focused on regular WSS patterns (Feintuch et al, 2007;Greve et al, 2006;Huo et al, 2008;Suo et al, 2007;Willett et al, 2010;Yap et al, 2014) are not affected much by our results.…”
Section: Implications For the Interpretation Of Previously Published mentioning
confidence: 44%
See 2 more Smart Citations
“…Many authors have tried to link local disease patterns to focal zones of locally disturbed shear stress using rigid-walled models of either the aortic arch (Assemat et al, 2014;Feintuch et al, 2007;Suo et al, 2007;Yap et al, 2014), the abdominal aorta (Ford et al, 2011;Greve et al, 2006;Trachet et al, 2011b;Willett et al, 2010) or both (Hoi et al, 2011;Huo et al, 2008;Van Doormaal et al, 2014). The findings of publications that focused on regular WSS patterns (Feintuch et al, 2007;Greve et al, 2006;Huo et al, 2008;Suo et al, 2007;Willett et al, 2010;Yap et al, 2014) are not affected much by our results.…”
Section: Implications For the Interpretation Of Previously Published mentioning
confidence: 44%
“…The findings of publications that focused on regular WSS patterns (Feintuch et al, 2007;Greve et al, 2006;Huo et al, 2008;Suo et al, 2007;Willett et al, 2010;Yap et al, 2014) are not affected much by our results. However, some findings of publications that focused on the oscillatory patterns of WSS (Assemat et al, 2014;Ford et al, 2011;Hoi et al, 2011;Trachet et al, 2011b;Van Doormaal et al, 2014) might need to be re-interpreted. In this respect it is important to keep in mind that our results were obtained in the carotid artery, and our conclusions may therefore not be valid in other aspects of the aorta.…”
Section: Implications For the Interpretation Of Previously Published mentioning
confidence: 99%
See 1 more Smart Citation
“…A mouse-specific 3D geometry of the aortic lumen containing four side branches was obtained in vivo, by segmentation of micro-CT (Triumph, Gamma Medica) images in Mimics (Materialise). In order to obtain sufficient contrast during the imaging process the mouse was intravenously injected with Aurovist (Nanoprobes), a contrast agent which provided satisfying results in earlier studies [1]. Using pyFormex [24] a structured grid was projected onto the from segmentation resulting outer surface yielding a hexahedral mesh for the aortic wall, Figure 4a, according to the method of De Santis et al [25].…”
Section: Example 2: In Vivo Stress Incorporation In a Mouse-specific mentioning
confidence: 99%
“…Together with pressure measurements there is sufficient data available to include patient-specific boundary conditions in computational fluid dynamics (CFD), computational structural dynamics (CSD) and even fluid-structure interaction (FSI) simulations. In CFD models the flow-related measurements can be imposed directly [1] or incorporated into windkessel and/or 1D models [2] at the inlet and outlets. In CSD models the in vivo data can be used to optimize the constitutive law for the tissue material [3] originally obtained by fitting ex vivo measurements.…”
Section: Introductionmentioning
confidence: 99%