2008
DOI: 10.1016/j.snb.2007.11.056
|View full text |Cite
|
Sign up to set email alerts
|

An inlaying ultra-thin carbon paste electrode modified with functional single-wall carbon nanotubes for simultaneous determination of three purine derivatives

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
14
0

Year Published

2010
2010
2018
2018

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 43 publications
(15 citation statements)
references
References 31 publications
1
14
0
Order By: Relevance
“…More recently, an inlaying ultra-thin carbon paste electrode modified with functional single-wall carbon nanotubes was developed for simultaneous determination of three purine derivatives [50]. To achieve good selectivity and sensitivity, other workers utilised fast scan voltammetry (FSV) at bare carbon fibre electrodes [55].…”
mentioning
confidence: 99%
“…More recently, an inlaying ultra-thin carbon paste electrode modified with functional single-wall carbon nanotubes was developed for simultaneous determination of three purine derivatives [50]. To achieve good selectivity and sensitivity, other workers utilised fast scan voltammetry (FSV) at bare carbon fibre electrodes [55].…”
mentioning
confidence: 99%
“…It can be seen that there are regular grooves distributed on its surface. Carbon paste can only be inlayed effectively to constitute a uniform IUCP film with the presence of these long and narrow grooves [29]. Figure 1B shows the SEM image of the IUCP film on nichrome substrate after shake and pitch from the 40 cm height, which indicates that the IUCP film is very stable and firm.…”
Section: Physical Characterizationmentioning
confidence: 99%
“…Then, its surface properties were examined by cyclic voltammetry using K 4 3À appears at about 0.3 V and the corresponding reduction one is minor. This is because the nichrome is too hard to be served as the working electrode for electroanalysis, directly [28,29]. A pair of evident oxidation -reduction peaks is observed at the non-preanodized IUCPE (curve b).The oxidation peak potential appears at 0.33 V and the reduction one at 0.17 V, respectively.…”
Section: The Electrochemical Properties Of Paiucpementioning
confidence: 99%
“…In brief, this paper focuses on the influencing mechanisms of the PAIUCEP on electrochemical oxidation of Xa and HXa, as well as the simultaneous determination of the Xa and HXa in human urine. Compared to the electrodes used in literatures, [9][10][11][12][13][14] this electrode is simple to prepare, low cost and avoids complex modification. Therefore, it is easier to popularize in conventional laboratory, and has a wide application prospect in the future.…”
Section: Introductionmentioning
confidence: 99%