2018 International Conference on Simulation of Semiconductor Processes and Devices (SISPAD) 2018
DOI: 10.1109/sispad.2018.8551751
|View full text |Cite
|
Sign up to set email alerts
|

An Improved Random Path Length Algorithm for p-i-n and Staircase Avalanche Photodiodes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
14
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(14 citation statements)
references
References 19 publications
0
14
0
Order By: Relevance
“…In [38] we have also shown that if different trials are run for pairs generated at the same position x and for each of them a gain m i is found, the RPL can be used to compute M = 〈m i 〉 and F 〈m 2 i 〉/M 2 providing exactly the same results as obtained with the numerical solution of Eqs 4-10.…”
Section: Improved Random-path-length Algorithm For Time Response To S...mentioning
confidence: 55%
See 2 more Smart Citations
“…In [38] we have also shown that if different trials are run for pairs generated at the same position x and for each of them a gain m i is found, the RPL can be used to compute M = 〈m i 〉 and F 〈m 2 i 〉/M 2 providing exactly the same results as obtained with the numerical solution of Eqs 4-10.…”
Section: Improved Random-path-length Algorithm For Time Response To S...mentioning
confidence: 55%
“…In [38] we have shown that the RPL algorithm can be applied to any functional form of α(x, x′), focusing on the model in [25] (i.e., Eq. 16 plus Eq.…”
Section: Improved Random-path-length Algorithm For Time Response To S...mentioning
confidence: 99%
See 1 more Smart Citation
“…To assess the influence of the sequence of steps on the device bandwidth, we run calculations using the Random Path Length algorithm presented in [17], which is an improved version, consistent with the definition of effective field of Eq. 6, of the one initially proposed by [18], [19].…”
Section: Numerical Resultsmentioning
confidence: 99%
“…The drawback of an increased number of steps is the longer multiplication region and thus longer time response to single photon absorption. The Random Path Length (RPL) implementation of the EBHDM [21] describes the time evolution of the current pulse and can be used to determine the When considering X-ray spectroscopy as a relevant application, one should remind that the diode current is processed by a leaky integrator followed by an CR-RC shaper. The overall transfer function of the system is approxi-…”
Section: Time Responsementioning
confidence: 99%