2020
DOI: 10.1016/j.reactfunctpolym.2020.104564
|View full text |Cite
|
Sign up to set email alerts
|

An improved metal cation capture on polymer with graphene oxide synthesized by gamma radiation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
3
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 22 publications
(4 citation statements)
references
References 74 publications
0
3
0
Order By: Relevance
“…The total yield of the radiotracer consists of free [ 125 I] -iodide and [ 125 I] -ZEN it is calculated from the percentage (%), on TLC at RTs (retention times) 0.0 and 0.9–1.0 respectively. HPLC analysis revealed the following, the purity for [ 125 I]-ZEN reached 99 % [ [101] , [102] , [103] , [104] , [105] , [106] , [107] , [108] , [109] , [110] , [111] , [112] , [113] , [114] , [115] , [116] , [117] , [118] , [119] , [120] ]. The Retention times values for both the free iodide and the labeled molecule [ 125 I]-ZEN existed at 4.5 and 15.8 min, respectively, with regard to the retention time for ZEN that was 14.7 min ( Fig.…”
Section: Resultsmentioning
confidence: 99%
“…The total yield of the radiotracer consists of free [ 125 I] -iodide and [ 125 I] -ZEN it is calculated from the percentage (%), on TLC at RTs (retention times) 0.0 and 0.9–1.0 respectively. HPLC analysis revealed the following, the purity for [ 125 I]-ZEN reached 99 % [ [101] , [102] , [103] , [104] , [105] , [106] , [107] , [108] , [109] , [110] , [111] , [112] , [113] , [114] , [115] , [116] , [117] , [118] , [119] , [120] ]. The Retention times values for both the free iodide and the labeled molecule [ 125 I]-ZEN existed at 4.5 and 15.8 min, respectively, with regard to the retention time for ZEN that was 14.7 min ( Fig.…”
Section: Resultsmentioning
confidence: 99%
“…However, it is important to ensure that the conditions of the irradiation and measurement are consistent between the sample and standard, as any differences could affect the accuracy of the analysis. Additional detailed descriptions can be found in refs [33][34][35][36][37][38]. Induced radioactivity was measured using an N-type HPGe detector, model Comp-100.250-S, manufactured by (EG &G ORTEC) with associated electronics and a computer-based multichannel analyzer.…”
Section: Analytical Technique (Naa)mentioning
confidence: 99%
“…A high-resolution gamma-ray spectrometer consists of a Canberra GC 6020 high purity germanium detector (HPGe) of efficiency 60 % coupled to 2026 Canberra spectroscopy amplifier and TRUMP 8K multichannel analyzer was used for detecting the natural radioactivity of samples. To decrease the background, the detector was surrounded by a 10 cm cylindrical lead shield with an inner layer of Cu to reduce gamma-ray scattering [36][37][38][39][40][41][42]. The efficiency calibration standard was International Atomic Energy Agency (IAEA) reference material RGU-1.…”
Section: Measurement Of Natural Radioactivitymentioning
confidence: 99%