2022
DOI: 10.1109/jestpe.2022.3155751
|View full text |Cite
|
Sign up to set email alerts
|

An Improved Design Procedure for a 10 kHz, 10 kW Medium-Frequency Transformer Considering Insulation Breakdown Strength and Structure Optimization

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 16 publications
(5 citation statements)
references
References 61 publications
0
3
0
Order By: Relevance
“…The surface potential near the electrode/ dielectric interface increases with the increase in polarization voltage. Figure 13d shows the charge density curve calculated using Equation (10). The homogeneous charge density near the [190] Copyright 2012, American Institute of Physics.…”
Section: Charge Characteristics At Electrode/dielectric Interfacementioning
confidence: 99%
See 1 more Smart Citation
“…The surface potential near the electrode/ dielectric interface increases with the increase in polarization voltage. Figure 13d shows the charge density curve calculated using Equation (10). The homogeneous charge density near the [190] Copyright 2012, American Institute of Physics.…”
Section: Charge Characteristics At Electrode/dielectric Interfacementioning
confidence: 99%
“…Interfaces created by solid–solid and solid–liquid polymer dielectrics have been widely used in advanced electronic devices and power equipment ( Figure ), [ 1–5 ] including multi‐layered dielectric contact regions in high voltage cables, [ 6–9 ] winding and dielectric contact regions in solid‐state transformers, [ 10 ] and filler/matrix contacts in composite materials for electronic device packaging. [ 11 ] Under the electric field, the interface charges are formed within various regions, indicating an improvement in electro‐acoustic, [ 12 ] electro‐optic, [ 13 ] and electro‐thermo [ 14 ] conversions in the flexible transducers.…”
Section: Introductionmentioning
confidence: 99%
“…Compared to conventional transformers, the ICT exhibits a significant distinction: its magnetic cores are segmented by insulating sheets with a high dielectric capability. This segmentation leads to a considerable amount of magnetic flux leakage, resulting in two unfavorable consequences: (1) a reduction in the induced voltage of the secondary windings; and (2) an increase in leakage inductance and output impedance [10]. The voltage doubling rectifier circuit converts the three-phase AC output from the secondary windings into DC.…”
Section: Introductionmentioning
confidence: 99%
“…impedance [10]. The voltage doubling rectifier circuit converts the three-phase AC output from the secondary windings into DC.…”
Section: Introductionmentioning
confidence: 99%
“…In [9], the characteristic parameters of partial discharge in transformer oil-paper insulation dielectric under fundamental frequency voltage superimposed on harmonic voltage with different frequencies, proportions, and phases are analysed. In [10], the partial discharge experiments on the air gap defect model of oil-paper insulation under DC voltage superposed with 6th, 12th, and 18th harmonic voltage. It is found that under high-frequency voltage space charges are easy to accumulate, and the number of partial discharges increases.…”
Section: Introductionmentioning
confidence: 99%