2018
DOI: 10.1016/j.ijepes.2017.12.001
|View full text |Cite
|
Sign up to set email alerts
|

An improved control strategy of 3P4W DVR systems under unbalanced and distorted voltage conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 28 publications
(7 citation statements)
references
References 27 publications
0
7
0
Order By: Relevance
“…Therefore, the droop control to determine the power-sharing among the interlinking inverters in the microgrid is not considered in this paper. From Figure 1, the modeling of the ILI is expressed through dq-axis components of the voltages and currents as [27][28][29] i rd = i cd − C f . e ld + ω e C f e lq (1)…”
Section: Proposed Control Scheme Of Hybrid Microgridmentioning
confidence: 99%
See 1 more Smart Citation
“…Therefore, the droop control to determine the power-sharing among the interlinking inverters in the microgrid is not considered in this paper. From Figure 1, the modeling of the ILI is expressed through dq-axis components of the voltages and currents as [27][28][29] i rd = i cd − C f . e ld + ω e C f e lq (1)…”
Section: Proposed Control Scheme Of Hybrid Microgridmentioning
confidence: 99%
“…It is worth noting that the gains of tracking controllers for both the FBT-based current and voltage controllers can be easily obtained through the pole-placement technique, where the desired poles are located on the left-half plane to obtain the closed-loop control stability [26,29].…”
Section: Control Of the Ili In Stand-alone Modementioning
confidence: 99%
“…By and large, it can be applied to protect critical loads by halting sudden alterations in voltage. The DVR is composed of injection transformers, protection circuit, bypass thyristor, passive filters, voltage source inverter (VSI), and energy storage (see Figure 1) [33][34][35][36][37][38][39][40][41]. When a voltage sag/swell happens, the DVR injects a series voltage ( ) into the network via the transformer.…”
Section: Dvr: Principlementioning
confidence: 99%
“…The issue of voltage sag leads to a high decrease in the whole DNS efficiency. One of the most common issues to attract the attention of many researchers [6,12,13,28,29], voltage sag can cause huge damage to DNS and equipment, customer demand, and industrial application. Thus, the voltage sag continues to pose huge challenges to the DNS.…”
Section: Introductionmentioning
confidence: 99%