2006
DOI: 10.1109/tbme.2006.883631
|View full text |Cite
|
Sign up to set email alerts
|

An Improved Adaptive Power Line Interference Canceller for Electrocardiography

Abstract: Power line interference may severely corrupt a biomedical recording. Notch filters and adaptive cancellers have been suggested to suppress this interference. We propose an improved adaptive canceller for the reduction of the fundamental power line interference component and harmonics in electrocardiogram (ECG) recordings. The method tracks. the amplitude, phase, and frequency of all the interference components for power line frequency deviations up to about 4 Hz. A comparison is made between the performance of… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

1
76
0

Year Published

2010
2010
2023
2023

Publication Types

Select...
6
4

Relationship

0
10

Authors

Journals

citations
Cited by 124 publications
(77 citation statements)
references
References 14 publications
1
76
0
Order By: Relevance
“…Secondly, high frequency noise was reduced with an eight order bidirectional IIR Chebyshev low pass filtering, whose cut-off frequency was 70 Hz [18]. Finally, powerline interference was removed through adaptive notch filtering, which preserves the ECG spectral information [19].…”
Section: Data Preprocessingmentioning
confidence: 99%
“…Secondly, high frequency noise was reduced with an eight order bidirectional IIR Chebyshev low pass filtering, whose cut-off frequency was 70 Hz [18]. Finally, powerline interference was removed through adaptive notch filtering, which preserves the ECG spectral information [19].…”
Section: Data Preprocessingmentioning
confidence: 99%
“…This type of filter has been shown useful in many biomedical applications [11,13,15], e.g. power line interference cancellation in ECG signals [22], and foetal ECG recording by using mother's ECG as a correlated noise source for adaptive noise cancellation [10].…”
mentioning
confidence: 99%
“…Then, unbiased vector s 0 is filtered to reduce signal disturbances and artifacts. Specifically, power line interference is reduced using an algorithm based on adaptive sinusoidal interference canceller that provides significant signal-to-noise ratio improvement Martens et al (2006). Also, the baseline wandering is cancelled out by the method described in Roddy (1991) that is based on a two-pole, phase-compensated filter, developed for realtime processing of long ECG segments.…”
Section: Preprocessing and Segmentationmentioning
confidence: 99%