2016
DOI: 10.1587/elex.13.20160429
|View full text |Cite
|
Sign up to set email alerts
|

An improved adaptive minimum dc-link voltage controller

Abstract: An improved controller for minimum dc-link-voltage control is proposed. due to its adaptive minimum dc-link voltage characteristic, it can obtain the better compensation performances, and also the minimum dc-link voltage control with self-charging process can be obtained as well as providing the dynamic harmonic currents, it has better dynamic and static characteristics. In order to make an accurate design of the proportional and integral gains, the design procedures of the improved minimum dc-link voltage con… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2017
2017
2018
2018

Publication Types

Select...
2
1

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 8 publications
(8 reference statements)
0
2
0
Order By: Relevance
“…Extracting the Harmonics which need to be compensated as reference current determine the steady state compensation accuracy and dynamic response capability of the active power filter. The traditional method based on the instantaneous reactive power theory [2,3,4,5,6], when the load steps dynamically, the DClink voltage may jump greatly. The SDFT method based on the abc coordinate system has been widely used in harmonic refrence current calculation [6,7,8,9], but it has an inherent latency of 1 fundamental grid cycle [10,11], which makes the system dynamic performance becomes poor, reducing the compensation accuracy.…”
Section: Introductionmentioning
confidence: 99%
“…Extracting the Harmonics which need to be compensated as reference current determine the steady state compensation accuracy and dynamic response capability of the active power filter. The traditional method based on the instantaneous reactive power theory [2,3,4,5,6], when the load steps dynamically, the DClink voltage may jump greatly. The SDFT method based on the abc coordinate system has been widely used in harmonic refrence current calculation [6,7,8,9], but it has an inherent latency of 1 fundamental grid cycle [10,11], which makes the system dynamic performance becomes poor, reducing the compensation accuracy.…”
Section: Introductionmentioning
confidence: 99%
“…It commonly consist of outer filter, electronic converter and DC-link capacitor. The researches of APF are mainly on reference current detection [2], DC-link voltage control [3], current control [4] and modulation [5]. The interactions between grid connected devices and the grid have drawn greater attentions [6,7].…”
Section: Introductionmentioning
confidence: 99%