1980
DOI: 10.1016/0039-128x(80)90030-6
|View full text |Cite
|
Sign up to set email alerts
|

An immunoassay for plasma cortisol based on chemiluminescence

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0
1

Year Published

1985
1985
2018
2018

Publication Types

Select...
5
3
2

Relationship

0
10

Authors

Journals

citations
Cited by 48 publications
(10 citation statements)
references
References 16 publications
0
9
0
1
Order By: Relevance
“…The sensitivity analysis did not reveal any material difference in overall percentage of adrenal insufficiency if only articles using a RIA were included, or if only articles using the ACTH250g test were included. Although the diagnostic performance of RIA in the routine evaluation of adrenocortical function is considered superior to other competitive-protein-binding analytical methods, like fluorimetry (91,92), the chemiluminescence immunoassay seems to have comparable diagnostic performance and accuracy to RIA (93). It should be kept in mind that test criteria for adrenal insufficiency available in clinical practice have a high sensitivity rather than a high specificity and therefore the number of false positive test results is not negligible.…”
Section: Discussionmentioning
confidence: 97%
“…The sensitivity analysis did not reveal any material difference in overall percentage of adrenal insufficiency if only articles using a RIA were included, or if only articles using the ACTH250g test were included. Although the diagnostic performance of RIA in the routine evaluation of adrenocortical function is considered superior to other competitive-protein-binding analytical methods, like fluorimetry (91,92), the chemiluminescence immunoassay seems to have comparable diagnostic performance and accuracy to RIA (93). It should be kept in mind that test criteria for adrenal insufficiency available in clinical practice have a high sensitivity rather than a high specificity and therefore the number of false positive test results is not negligible.…”
Section: Discussionmentioning
confidence: 97%
“…First, by using a human cortisol test method using chemiluminescence immunoassay (Kohen et al, 1980), the test sensitivity was 0.2 µg/dl. Second, by using salivary ELISA test method (Bennett and Hayssen, 2010), the sensitivity was 0.003 µg/dl.…”
Section: Methodsmentioning
confidence: 99%
“…Heparinized samples were centrifuged at 4000 × g for 5 minutes, and serum was collected and frozen at −80°C until the cortisol assay could be performed. Serum cortisol levels were later determined by using a solid phase, competitive chemiluminescent enzyme immunoassay as previously described …”
Section: Methodsmentioning
confidence: 99%