1997
DOI: 10.1016/s0099-2399(97)80055-6
|View full text |Cite
|
Sign up to set email alerts
|

An experimental study of the removal of cemented dowel-retained cast cores by ultrasonic vibration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
24
0

Year Published

2002
2002
2014
2014

Publication Types

Select...
4
2
2

Relationship

0
8

Authors

Journals

citations
Cited by 27 publications
(24 citation statements)
references
References 5 publications
0
24
0
Order By: Relevance
“…This same time period was used with success by Oliveira et al (6) for the removal of prefabricated posts cemented with zinc phosphate cement in a 10-mm extension, with a post displacement from the canal of 67%. Variations from 2 to 16 min (1,4,5,8,17) in vibration time necessary to dislodge the post can be attributed to extension or experimental design differences.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…This same time period was used with success by Oliveira et al (6) for the removal of prefabricated posts cemented with zinc phosphate cement in a 10-mm extension, with a post displacement from the canal of 67%. Variations from 2 to 16 min (1,4,5,8,17) in vibration time necessary to dislodge the post can be attributed to extension or experimental design differences.…”
Section: Discussionmentioning
confidence: 99%
“…The end tip of the ultrasound was positioned in the occlusal and lateral aspects of the post, bilaterally, for a period of one minute in each side. Yoshida et al (17) reports that the cement layer opposite to the ultrasound is destroyed before the one from the same side on which it had been placed. Transferring this reasoning to the present study, when the tip is positioned in three different directions, the cement breakage would occur apically and in two opposite lateral sides.…”
Section: Discussionmentioning
confidence: 99%
“…15,16 Reports evaluating the ability of ultrasound instruments to remove luted posts from teeth have shown a direct correlation between the vibrations generated and post loosening. 17,18 Because of the characteristics of the handpiece mechanism, the cutting instruments, and the speed of rotation, rotary instrumentation produces vibrations equivalent to those produced by ultrasound instruments. 19 Additionally, the vibrations produced by rotary diamond instruments in high-speed handpieces may affect the post/tooth cement layer, consequently jeopardizing post stability and retention.…”
Section: Declaration Of Interestsmentioning
confidence: 99%
“…26 The results of the present study showed that all the cast posts were successfully removed in a short time interval (mean time up to 2 minutes). Variations from 2 to 16 minutes 15,16,18,27,28 in vibration time necessary to dislodge the posts can be attributed to experimental design differences. 17 In the present study, an effort was made to maximize the energy transfer from the instrument tip to the post, evaluating the angle and the position of the tip in relation to the post, according other authors.…”
mentioning
confidence: 99%
“…The cement layer opposite to the ultrasound is destroyed before the one from the same side on which it had been placed. 28 The ultrasonic vibration induced fracture propagation in the cement itself, and also separation of cement from the mettalic cast. These findings suggesting that the resistance to ultrasonic vibration is smaller in the metal-cement interface than in the dentin-cement interface.…”
mentioning
confidence: 99%