2015
DOI: 10.1016/j.expthermflusci.2015.08.009
|View full text |Cite
|
Sign up to set email alerts
|

An experimental investigation of pure steam and steam–air mixtures condensation outside a vertical pin-fin tube

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
4
0
1

Year Published

2016
2016
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 40 publications
(6 citation statements)
references
References 26 publications
0
4
0
1
Order By: Relevance
“…Для інтенсифікації тепломасообмінних процесів у плівкових апаратах з вертикальною теплообмінною поверхнею використовують різноманітне оребрення [1][2][3][4][5][6][7][8][9][10]. Враховуючи тісний зв'язок питань гідродинаміки плівки рідини та інтенсивності теплообміну, доцільно проаналізувати основні параметри плівки та мінімальної щільності зрошення рідиною поверхні з повздовжнім оребренням.…”
Section: мета дослідженняunclassified
“…Для інтенсифікації тепломасообмінних процесів у плівкових апаратах з вертикальною теплообмінною поверхнею використовують різноманітне оребрення [1][2][3][4][5][6][7][8][9][10]. Враховуючи тісний зв'язок питань гідродинаміки плівки рідини та інтенсивності теплообміну, доцільно проаналізувати основні параметри плівки та мінімальної щільності зрошення рідиною поверхні з повздовжнім оребренням.…”
Section: мета дослідженняunclassified
“…In addition, condensation by forced and free convection was studied on tubes [31] and data obtained for many different types of tubes with different pressures and geometries. The transfer of heat was found to be significantly enhanced when the velocity was increased [32][33][34][35]. The coefficient of heat transfer relating to this kind of condensation was derived by Rose and Briggs.…”
Section: Introductionmentioning
confidence: 96%
“…In particular, with the development of seawater desalination and the nuclear power industry, the condensation heat transfer with a non-condensable gas is becoming a research focus. Earlier results studied few possibly trace amounts, of non-condensable gases [4,8] , geometries [16][17][18][19][20][21][26][27][28] , and flow patterns [6,29] , while only a few experiments involved the condensation heat transfer process with a high fractional non-condensable gas [7,15,[30][31][32][33][34] . The general trend the research follows is: attaining a more reasonable experimental system design, and then increased reliability of the measurement of variable parameters, especially the temperature of the condensing plate, temperature of the bulk vapor mixture, and gas-liquid interface temperature.…”
Section: .Introductionmentioning
confidence: 99%
“…Experiments with non-condensable gases ranging from 30% to 65% were conducted on a vertically mounted tube to evaluate the heat removal capacity of a passive cooling unit in a post-accident containment by Liu [15] . Tong [30] used a pin-fin tube in the condensation of pure steam and steam-air. He found that the enhancement ratio would maximally reach 1.8 with an air mass fraction larger than 90%.…”
Section: .Introductionmentioning
confidence: 99%