2007
DOI: 10.1016/j.bjoms.2006.12.002
|View full text |Cite
|
Sign up to set email alerts
|

An experimental in vivo analysis of the resorption to ultrasound activated pins (Sonic weld®) and standard biodegradable screws (ResorbX®) in sheep

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

6
41
0
2

Year Published

2011
2011
2023
2023

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 69 publications
(49 citation statements)
references
References 7 publications
6
41
0
2
Order By: Relevance
“…Two in vitro studies and four experimental animal trials have been carried out that demonstrated the excellent stability and handling characteristics of the osteosynthesis system (Table 2 6,16,17,21,22,26 ). The clinical studies that were performed on pediatric craniosynostosis patients also showed favourable outcomes with low complication rates (Table 3 4,5,7,24 ).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Two in vitro studies and four experimental animal trials have been carried out that demonstrated the excellent stability and handling characteristics of the osteosynthesis system (Table 2 6,16,17,21,22,26 ). The clinical studies that were performed on pediatric craniosynostosis patients also showed favourable outcomes with low complication rates (Table 3 4,5,7,24 ).…”
Section: Discussionmentioning
confidence: 99%
“…In craniofacial surgery a percentage of complications below 1% has been described as well as complication rates of up to 15.4% 9,13,25 . 21 Pilling et al…”
Section: Discussionmentioning
confidence: 99%
“…Rigid fixation with titanium miniplates was reportedly a superior technique when compared with resorbable miniplates [11][12][13] . Therefore, the present study focused on evaluating the biomechanical stability characteristics of titanium miniplates of varied shapes instead of evaluating rigid fixation methods.…”
Section: Discussionmentioning
confidence: 99%
“…This problem has been overcome by inserting pins instead of screws with the aid of ultrasound. It has been shown previously that the operation time required for applying osteosynthesis materials was reduced by 50% 21 . Since the pins are not exposed to tensional forces the material does not fracture 21 .…”
Section: Introductionmentioning
confidence: 90%
“…It has been shown previously that the operation time required for applying osteosynthesis materials was reduced by 50% 21 . Since the pins are not exposed to tensional forces the material does not fracture 21 . Like in every other field new advances in resorbable osteosynthesis have to prove their relevance over short and long term.…”
Section: Introductionmentioning
confidence: 90%