2013
DOI: 10.1524/ract.2013.2039
|View full text |Cite
|
Sign up to set email alerts
|

An electrochemical route to prepare planar 204Tl sources for the calibration of beta surface contamination monitors

Abstract: Tl / Autoradiography / Electrodeposition / Leachability / Polymer coating / Radioactive sourceSummary. This paper describes the utility of the electrochemical technique for the preparation of a circular planar 204 Tl source required for the calibration of beta surface contamination monitors. The electrolytic cell, the experimental set up used and the process of deposition are described. The factors that influence the electrodeposition of 204 Tl onto the circular copper substrate were investigated and a careful… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 24 publications
0
4
0
Order By: Relevance
“…The activity deposited on the anodic titanium substrate was therefore kept 5 % more than the required activity based on the experimental results, in order to compensate the attenuation effects of the coating material. The concentration of the polystyrene in benzene was kept at 150 mg/mL based on the information derived from the reported procedure [5,6,10,12,16]. As seen from the results, polymer coating of the radioactive source was found to be effective in retarding the leachability to 0.0049 ± 0.0017 %, which is well within the limit prescribed by AERB, India [22].…”
Section: Leachabilitymentioning
confidence: 70%
See 3 more Smart Citations
“…The activity deposited on the anodic titanium substrate was therefore kept 5 % more than the required activity based on the experimental results, in order to compensate the attenuation effects of the coating material. The concentration of the polystyrene in benzene was kept at 150 mg/mL based on the information derived from the reported procedure [5,6,10,12,16]. As seen from the results, polymer coating of the radioactive source was found to be effective in retarding the leachability to 0.0049 ± 0.0017 %, which is well within the limit prescribed by AERB, India [22].…”
Section: Leachabilitymentioning
confidence: 70%
“…The active area of the source was coated with polystyrene by the dip-pull method following the reported procedure [5,6,10,12,16]. The 90 Sr/ 90 Y deposited source was immersed into a solution of polystyrene in benzene solution (150 mg/mL), stirred using magnetic stirrer, for 3 min and taken out with a tweezers.…”
Section: Optimization Of Electro-deposition Parametersmentioning
confidence: 99%
See 2 more Smart Citations