2023
DOI: 10.1016/j.bios.2023.115081
|View full text |Cite
|
Sign up to set email alerts
|

An electrochemical immunosensor for the detection of Glypican-3 based on enzymatic ferrocene-tyramine deposition reaction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 10 publications
(6 citation statements)
references
References 29 publications
0
5
0
Order By: Relevance
“…W. Lu et al used the magnetic bead-GPC3 antibody-GPC3 antigen-HRP coupling as a catalytic inducer to induce the deposition of large amounts of ferrocene-tyramine (Fc-Tyr) on the surface of the SPCE/Au NP/3-mercaptopropionic acid (MPA)/Tyr electrode, generating enhanced ferrocene redox currents so that the analyte concentration could be quantified by recording the current signal of the Fc molecules, and the concentration range is 0.1–1 ng ml −1 . 66 (Fig. 7b) P. Chikhaliwala et al used magnetite nanoparticles (Fe 3 O 4 NPs) functionalized with first-generation poly-amidoamine dendrimers (G1; PAMAM) as an electrochemical biosensing platform for early diagnosis of HCC which can simultaneously measure GPC3 from a single sample.…”
Section: Non-optical Inspection Methodsmentioning
confidence: 99%
“…W. Lu et al used the magnetic bead-GPC3 antibody-GPC3 antigen-HRP coupling as a catalytic inducer to induce the deposition of large amounts of ferrocene-tyramine (Fc-Tyr) on the surface of the SPCE/Au NP/3-mercaptopropionic acid (MPA)/Tyr electrode, generating enhanced ferrocene redox currents so that the analyte concentration could be quantified by recording the current signal of the Fc molecules, and the concentration range is 0.1–1 ng ml −1 . 66 (Fig. 7b) P. Chikhaliwala et al used magnetite nanoparticles (Fe 3 O 4 NPs) functionalized with first-generation poly-amidoamine dendrimers (G1; PAMAM) as an electrochemical biosensing platform for early diagnosis of HCC which can simultaneously measure GPC3 from a single sample.…”
Section: Non-optical Inspection Methodsmentioning
confidence: 99%
“…As shown in Table S1, the dynamic range of this TSA-amplified PGM immunoassay with 5 orders of magnitude is also better than that of PGM-based immunoassays. Moreover, compared with the reported TSA-based electrochemical immunoassay, 27 chemiluminescence immunoassay, 28 surface-enhanced Raman scattering immunoassay, 29 and electrochemiluminescence immunoassay, 30 the proposed TSA-PGM immunoassay possesses unique advantages that are simple, cost-effective, and easy to popularize and is not limited by the sophisticated equipment and technologies and special laboratories. Therefore, the TSA-PGM immunoassay provides a simple and efficient strategy for the detection of a low level of proteins by integration of the TSA reaction and PGM readout.…”
Section: ■ Introductionmentioning
confidence: 99%
“…15 At the same time, electrochemistry-based POCT devices have gained great attention because of their several advantages, including high sensitivity, low cost, rapid response and easy operation. 16,17 For example, Chen et al reported an integrated flexible electrode for the rapid detection of cancer-related RNA in human urine samples with excellent sensitivity and stability. 18…”
Section: Introductionmentioning
confidence: 99%
“…15 At the same time, electrochemistrybased POCT devices have gained great attention because of their several advantages, including high sensitivity, low cost, rapid response and easy operation. 16,17 For example, Chen et al reported an integrated flexible electrode for the rapid detection of cancer-related RNA in human urine samples with excellent sensitivity and stability. 18 To fabricate microelectrodes for integrated electrochemical immunosensors, screen printing technology is considered an ideal technique because of its unique advantages such as simplicity, speed, efficiency and mass production.…”
Section: Introductionmentioning
confidence: 99%