1987
DOI: 10.1109/tei.1987.298914
|View full text |Cite
|
Sign up to set email alerts
|

An Electric Stress-Pulse Technique for The Measurement of Charges in A Plastic Plate Irradiated by an Electron Beam

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
36
0

Year Published

1994
1994
2023
2023

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 119 publications
(36 citation statements)
references
References 9 publications
0
36
0
Order By: Relevance
“…The PEA method was originally conceived for space charge measurements on thin samples between plane parallel electrodes [26], but later it was extended successfully to the coaxial cable geometry [27] using the system shown in Figure 2.A (after [2]): a and b are the inner and outer radii of the insulation, respectively; ρ(r) is the volume space charge density at radius r; s, l, and c are the thickness of the outer semicon, the distance between the outer semicon and the piezoelectric transducer -a polyvinylidene (PVDF) film -and the position of the piezo device, respectively. R and C are respectively the resistance and capacitance of the PEA measurement system, V is the voltage of the DC source, and v p (t) is the time-dependent applied voltage pulse.…”
Section: Pulse-electro Acoustic (Pea) Methodsmentioning
confidence: 99%
“…The PEA method was originally conceived for space charge measurements on thin samples between plane parallel electrodes [26], but later it was extended successfully to the coaxial cable geometry [27] using the system shown in Figure 2.A (after [2]): a and b are the inner and outer radii of the insulation, respectively; ρ(r) is the volume space charge density at radius r; s, l, and c are the thickness of the outer semicon, the distance between the outer semicon and the piezoelectric transducer -a polyvinylidene (PVDF) film -and the position of the piezo device, respectively. R and C are respectively the resistance and capacitance of the PEA measurement system, V is the voltage of the DC source, and v p (t) is the time-dependent applied voltage pulse.…”
Section: Pulse-electro Acoustic (Pea) Methodsmentioning
confidence: 99%
“…The pulse electrostatic stress (PEA) method [7] was used as a technology to measure the space charge. As for measurements, the space charge distribution was measured in phases which matched the peak voltage of the positive electrode or the negative electrode as shown in Fig.…”
Section: Materials and Experimental Methodsmentioning
confidence: 99%
“…The electro-acoustic stress pulse method has been used by Takada [92][93][94]97,98], Cooke [101,103] and others [95,96,106] in the evaluation of the space charge profiles in thick slabs of several polymer dielectrics charge by electron beam irradiation. Cooke [lo21 also has utilized this method in scanning charges accumulated on a gas-solid interface.…”
Section: Electro-acoustic Stress Pulse Methodsmentioning
confidence: 99%