2016
DOI: 10.1139/cjc-2016-0092
|View full text |Cite
|
Sign up to set email alerts
|

An eco-friendly method for analysis of sulfonamides in water samples using a multi-pumping system

Abstract: A new methodology for determination of sulfonamides (sulfaquinoxaline, sulfathiazole, and sulfadimethoxine) in water samples was developed by coupling an automated multi-pumping flow system (MPFS) with a liquid waveguide capillary cell (LWCC; pathlength, 100 cm) and a spectrophotometric detector. The method is based on the reaction between sulfonamides and p-dimethylaminocinnamaldehyde (p-DAC) in the presence of sodium dodecylsulfate (SDS) in dilute acid medium (hydrochloric acid), with measurement of the reac… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 35 publications
0
2
0
Order By: Relevance
“…Other methods proposed for evaluation of sulfonamides in environmental waters using the same colorimetric reaction either require a dedicated automated manifold that is not commercially available [47,50] or involve a desorption step of the retained SMZ in the solid support, making the analytical process longer and requiring more organic solvent and the use of microplate equipment [43]. Moreover, compared to other methods developed for screening [43,50,51], the present method offers similar LOD values, particularly when using 25 mL of sample.…”
Section: Figures Of Merit and Application To Environmental Screeningmentioning
confidence: 91%
See 1 more Smart Citation
“…Other methods proposed for evaluation of sulfonamides in environmental waters using the same colorimetric reaction either require a dedicated automated manifold that is not commercially available [47,50] or involve a desorption step of the retained SMZ in the solid support, making the analytical process longer and requiring more organic solvent and the use of microplate equipment [43]. Moreover, compared to other methods developed for screening [43,50,51], the present method offers similar LOD values, particularly when using 25 mL of sample.…”
Section: Figures Of Merit and Application To Environmental Screeningmentioning
confidence: 91%
“…Other methods proposed for evaluation of sulfonamides in environmental waters using the same colorimetric reaction either require a dedicated automated manifold that is not commercially available [47,50] or involve a desorption step of the retained SMZ in the solid support, making the analytical process longer and requiring more organic solvent and the use of microplate equipment [43]. Moreover, compared to other methods developed for screening [43,50,51], the present method offers similar LOD values, particularly when using 25 mL of sample. Finally, there are methods that provided lower LOD values, but they require chromatographic equipment connected to fluorimeters [52] or mass spectrometry detectors [53][54][55], and this type of technology cannot be applied in the field in the manner of our proposed mobile device sensor.…”
Section: Figures Of Merit and Application To Environmental Screeningmentioning
confidence: 91%