2006
DOI: 10.1088/0964-1726/15/2/016
|View full text |Cite
|
Sign up to set email alerts
|

An autonomous shunt circuit for vibration damping

Abstract: This paper describes the implementation of an autonomous switching resistor-inductor (R-L) shunt circuit for the control of structure vibration. The resulting switch shunt circuit, compared to present shunt circuit techniques, does not require a power for its operation and is almost as effective. Moreover, experiments show that the damping performance is robust against temperature variations due to environmental conditions, whereas present shunt circuits lose their damping performance. The proposed autonomous … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
59
0

Year Published

2009
2009
2018
2018

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 68 publications
(59 citation statements)
references
References 15 publications
(23 reference statements)
0
59
0
Order By: Relevance
“…Usually the switching action is performed at the extremum of the displacement motion. However, in the autonomous SSD techniques, the task of the DSP is taken up by an additional collocated piezoelectric transducer which acts as a sensor to generate an electrical signal in proportion to the displacement and the strain of the vibrating structure [18]. A low pass filter is used in the autonomous shunt circuit which filters the sensor voltage V s to generate a control voltage V c in order to control and power up the switch.…”
Section: Implementation Of Autonomous Ssdnci Techniquementioning
confidence: 99%
See 4 more Smart Citations
“…Usually the switching action is performed at the extremum of the displacement motion. However, in the autonomous SSD techniques, the task of the DSP is taken up by an additional collocated piezoelectric transducer which acts as a sensor to generate an electrical signal in proportion to the displacement and the strain of the vibrating structure [18]. A low pass filter is used in the autonomous shunt circuit which filters the sensor voltage V s to generate a control voltage V c in order to control and power up the switch.…”
Section: Implementation Of Autonomous Ssdnci Techniquementioning
confidence: 99%
“…In the work of Niederberger and Morari [18], a lowamplitude sinusoidal control voltage V c was used to drive the switch which resulted in the poor control performance. Actually the low pass filter used in their work, reduced the piezo sensor voltage V s by at least 10 times resulting in inefficient switching with large electrical losses.…”
Section: Implementation Of Autonomous Ssdnci Techniquementioning
confidence: 99%
See 3 more Smart Citations