An approach to the reconstruction of true concentration profile from transient signal in spatially resolved analysis by means of laser ablation ICP MS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
36
0

Year Published

2003
2003
2017
2017

Publication Types

Select...
8
1
1

Relationship

0
10

Authors

Journals

citations
Cited by 29 publications
(37 citation statements)
references
References 34 publications
1
36
0
Order By: Relevance
“…Laser energy profile has been reported as responsible for ablation crater structure [31][32][33]. However, other parameters should be taken into account, e.g., viscosity of melt, wettability melt-solid, melt mobility, and surface tension of the melt that is influenced by the gas environment, too.…”
Section: Melt Pool In the Samplementioning
confidence: 98%
“…Laser energy profile has been reported as responsible for ablation crater structure [31][32][33]. However, other parameters should be taken into account, e.g., viscosity of melt, wettability melt-solid, melt mobility, and surface tension of the melt that is influenced by the gas environment, too.…”
Section: Melt Pool In the Samplementioning
confidence: 98%
“…135 A time lag between laser firing and signal detection occurs during which the laser might move forward, which needs to be considered when linking line-scan signals to specific locations on a sample. 136 Plotnikov et al 137 developed a mathematical model for establishing the correlation between spatial and temporal coordinates of the analytical signal from line scans correctly. The model is based on the estimation of the signal delay caused by material washout as an effect of the size of the laser ablation chamber.…”
Section: Depth Profiling and Three-dimensional Mappingmentioning
confidence: 99%
“…A number of studies have attempted to produce generalised approaches to this phenomenon. For example, Plotnikov et al (2002) applied mathematical post-processing of laser ablation data to deconvolve the complexity of the analytical response, while Sanborn and Telmer (2003) provided a practical method for the assessment of spatial resolution in line scans. The extent of this problem, however, is controlled very strongly by ablation cell design and thus considerable effort has been expended in both commercial and research organisations to design systems for "rapid washout".…”
Section: Mixing Within the Cellmentioning