2007
DOI: 10.1016/j.chroma.2007.02.007
|View full text |Cite
|
Sign up to set email alerts
|

An aniline-based fiber coating for solid phase microextraction of polycyclic aromatic hydrocarbons from water followed by gas chromatography-mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
54
0

Year Published

2008
2008
2017
2017

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 121 publications
(56 citation statements)
references
References 34 publications
2
54
0
Order By: Relevance
“…After seawater sample (with 10% ethanol) was added with internal standards of Nap-d 8 , Ace-d 10 , Phe-d 10 , Pyr-d 10 and BaP-d 12 , an aliquot (1.0-100 mL) of the mixture was introduced into the HPLC system through the HPLC pump 1. The inlet tubing was rinsed with the sample for 10 min before loading.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…After seawater sample (with 10% ethanol) was added with internal standards of Nap-d 8 , Ace-d 10 , Phe-d 10 , Pyr-d 10 and BaP-d 12 , an aliquot (1.0-100 mL) of the mixture was introduced into the HPLC system through the HPLC pump 1. The inlet tubing was rinsed with the sample for 10 min before loading.…”
Section: Methodsmentioning
confidence: 99%
“…Solidphase microextraction with different coating materials or polymeric fiber was employed for the determination of PAHs in tap water, river water or rainwater, and these techniques provided large extraction capacity and high sensitivity ranged ng L −1 level when coupling with gas chromatography-mass spectrometry (GC-MS)/HPLC. [11][12][13] However, the evaporation of the eluate reduced the recoveries of PAHs having 2 to 3 rings which have high vapor pressures.…”
mentioning
confidence: 99%
“…The uses of polymeric material have been developed for extraction of PAHs in water samples in order to minimize the solvent waste [25,26]. In one of the D-µ-SPE procedure, 50 mg of nanoporous CaCO 3 was first conditioned with dichloromethane for 5 min and then placed in 5 ml water sample in a 10 ml glass centrifuge vial.…”
Section: Dispersive Micro-solid Phase Extraction (D-µ-spe)mentioning
confidence: 99%
“…The one-step production of films, the fiber-to-fiber reproducibility and the control of fiber thickness by changing the number of scan cycles must be highlighted among its advantages. [19][20][21] Some organic solvents and supporting electrolytes have been used in the electropolymerization of polythiophene film and its derivatives. 15,16,20 The electrochemical properties of polythiophene films largely depend on the supporting electrolyte, especially on the type of anion.…”
Section: Electropolymerization Processmentioning
confidence: 99%