An Adaptive Synchronous-Reference-Frame Phase-Locked Loop for Power Quality Improvement in a Polluted Utility Grid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
123
0
3

Year Published

2014
2014
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 265 publications
(126 citation statements)
references
References 43 publications
0
123
0
3
Order By: Relevance
“…A major challenge of PLLs is how to quickly and accurately estimate the phase angle and frequency when the grid voltage is distorted. To overcome this challenge, combining filtering techniques into the structure of PLLs has been proposed in the literature [13][14][15][16][17][18][19][20][21][22][23][24]. Reference [14] used a double, or more synchronous reference frame (DSRF/MSRF), to realize the decoupling between the fundamental negative sequence and the positive sequence components, and then locking the phase angle by extracting the fundamental positive sequence component, which can realize a fast and dynamic response.…”
Section: Introductionmentioning
confidence: 99%
“…A major challenge of PLLs is how to quickly and accurately estimate the phase angle and frequency when the grid voltage is distorted. To overcome this challenge, combining filtering techniques into the structure of PLLs has been proposed in the literature [13][14][15][16][17][18][19][20][21][22][23][24]. Reference [14] used a double, or more synchronous reference frame (DSRF/MSRF), to realize the decoupling between the fundamental negative sequence and the positive sequence components, and then locking the phase angle by extracting the fundamental positive sequence component, which can realize a fast and dynamic response.…”
Section: Introductionmentioning
confidence: 99%
“…The grid current should follow the fundamental positive sequence component of the grid voltage with a preset current value. That's why so many phase-locked loops have been proposed in recent years [10][11][12][13][14][15][16][17]. In [10], a method for extracting the fundamental frequency positive-sequence voltage was proposed based on the simple mathematical transformations.…”
Section: Introductionmentioning
confidence: 99%
“…Another interesting method in [11] utilized the decoupled double synchronous reference frame phase-locked loop. An improvement in [12] used an adaptive synchronous reference frame phaselocked loop. A multiple reference frame based phaselocked loop was reported in [13] to extract the fundamental positive sequence component of the grid voltage.…”
Section: Introductionmentioning
confidence: 99%
“…Various synchronization techniques have been proposed in literatures. The zero crossing detection methods [3], the space-vector filtering (SVF) method [4], the artificial neural networks (ANN) method [5], the recursive weighted least-squares estimation (WLSE) algorithm [6], the discrete Fourier transform (DFT) and its modifications [7], the methods based on the concept of adaptive notch filtering (ANF) [8], the Kalman filtering technique [9], the frequency-locked loop (FLL) methods [10], three phase open-loop phase-locked method [11] and the phase-locked loop (PLL) algorithms [12,13] are among the existing synchronization techniques.…”
Section: Introductionmentioning
confidence: 99%