2010
DOI: 10.1080/00032710903502173
|View full text |Cite
|
Sign up to set email alerts
|

Amperometric Determination of Cholesterol-Reducing Drug, Ezetimibe, Using Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotubes and Sodium Dodecylsulfate

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2011
2011
2021
2021

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 23 publications
0
3
0
Order By: Relevance
“…Hypocholesterolemic products were determined in pharmaceuticals formulations using unmodified ) and multi-walled carbon nanotubes-modified glassy carbon electrodes (Jalali et al 2010). Figure 2 shows a typical amperometric graph illustrating the current response of carbon paste electrode in flux injection analysis of benzocaine with injections of the Brought to you by | SUNY Binghamton Authenticated Download Date | 11/18/14 5:23 PM analyte in decreasing concentrations taken from Dejmkova et al (2013).…”
Section: Amperometric Methodsmentioning
confidence: 99%
“…Hypocholesterolemic products were determined in pharmaceuticals formulations using unmodified ) and multi-walled carbon nanotubes-modified glassy carbon electrodes (Jalali et al 2010). Figure 2 shows a typical amperometric graph illustrating the current response of carbon paste electrode in flux injection analysis of benzocaine with injections of the Brought to you by | SUNY Binghamton Authenticated Download Date | 11/18/14 5:23 PM analyte in decreasing concentrations taken from Dejmkova et al (2013).…”
Section: Amperometric Methodsmentioning
confidence: 99%
“…However, these techniques present a number of critical drawbacks, including the requirement of expensive solvents and instruments for high-performance liquid chromatography. Thus, efforts have been made to overcome these drawbacks by promoting the use of electroanalytical methods for assaying EZT [28][29][30][31][32][33]. Compared with other techniques, electroanalytical methods advantages an excellent limit of detection (LD � 10 À 12 mol L À 1 ), small sample requirements, and short analysis time.…”
Section: Introductionmentioning
confidence: 99%
“…A linear amperometric calibration curve was obtained in the range of 1.2-78 M (0.5-32.0 g/mL) of ezetimibe, with a sensitivity of 88.6 nA/ M and a detection limit of 300 nM (0.12 g/mL). 13 Reviewing the literature revealed that, up to the present time, nothing has been published concerning the determination of ezetimibe in plasma by electrochemical sensors. The aim of this work is to develop a simple validated, sensitive, and time saving coated wire membrane electrodes for the determination of ezetimibe in pure form, pharmaceutical preparations and biological fluids.…”
Section: Introductionmentioning
confidence: 99%