Alternative spectrophotometric method for standardization of chlorite aqueous solutions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
21
0

Year Published

2010
2010
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 32 publications
(22 citation statements)
references
References 8 publications
1
21
0
Order By: Relevance
“…In Figure 8, the ferric resting enzyme is depicted in black, the first spectrum monitored 1 ms after mixing with chlorite (final concentrations either 200 or 1000 μM) is shown in cyan and the final spectrum, monitored after 20 or 60 s, in red. During very rapid degradation of 200 μM chlorite (ε 260nm = 155 M − 1 ·cm − 1 ) [49] at k obs of 8.7 s − 1 , wild-type NdCld loses Soret absorbance. This suggests haeme bleaching as reported previously (Figure 8) [25].…”
Section: Impact Of H-bond Disruption On Chlorite Degradation and Enzymentioning
confidence: 99%
“…In Figure 8, the ferric resting enzyme is depicted in black, the first spectrum monitored 1 ms after mixing with chlorite (final concentrations either 200 or 1000 μM) is shown in cyan and the final spectrum, monitored after 20 or 60 s, in red. During very rapid degradation of 200 μM chlorite (ε 260nm = 155 M − 1 ·cm − 1 ) [49] at k obs of 8.7 s − 1 , wild-type NdCld loses Soret absorbance. This suggests haeme bleaching as reported previously (Figure 8) [25].…”
Section: Impact Of H-bond Disruption On Chlorite Degradation and Enzymentioning
confidence: 99%
“…It is currently believed that the most accurate and reliable method for measuring ClO 2 gas concentrations is to trap ClO 2 gas in KI solution and then to measure ClO 2 -ions using ion chromatography [27] . However, this method cannot be easily used to measure the gas concentrations of actual living rooms for longer periods of time.…”
Section: Discussionmentioning
confidence: 99%
“…Pharmacology 2017;99:114-120 DOI: 10.1159/000452339 117 and titrating it using Na 2 S 2 O 3 is a reliable method for measuring the amount of ClO 2 [27] . In fact, we collected almost 100% of the ClO 2 gas as ClO 2 -using the KI solution ( fig.…”
Section: Disinfection Of Room Air Using Clo 2 Gasmentioning
confidence: 99%
“…Traditionally, chloride ions have been determined by argentometry, however this method suffers from long experimental times and poor selectivity. Other techniques have been developed for chloride quantification: chromatography [1,2], spectroscopy [3,4], voltammetry [5] and turbidimetry [6]. Even when these techniques are accurate and precise, their operation, maintenance and possible miniaturization are very expensive.…”
Section: Introductionmentioning
confidence: 99%