1992
DOI: 10.1093/toxsci/18.3.328
|View full text |Cite
|
Sign up to set email alerts
|

Alterations in Rat Flash and Pattern Reversal Evoked Potentials after Acute or Repeated Administration of Carbon Disulfide (CS2)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

2
11
0

Year Published

1997
1997
2018
2018

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(13 citation statements)
references
References 0 publications
2
11
0
Order By: Relevance
“…Latencies of all peaks were measured in milliseconds from the stimulus onset to the point in time corresponding to 1st h (mean value) 3rd h (mean value) 2nd h (mean value) 4th 5th h (mean value) -a b the greatest excursion; the amplitude measurements (ÌV) were from peak to peak. Preliminary studies in our laboratories on recording cortical (active) versus body (reference) electrodes and data in the literature [27] confirmed that the potentials originate in the cortical tissue, and are relatively indifferent to retinal potentials.…”
Section: F-veps Investigationmentioning
confidence: 71%
“…Latencies of all peaks were measured in milliseconds from the stimulus onset to the point in time corresponding to 1st h (mean value) 3rd h (mean value) 2nd h (mean value) 4th 5th h (mean value) -a b the greatest excursion; the amplitude measurements (ÌV) were from peak to peak. Preliminary studies in our laboratories on recording cortical (active) versus body (reference) electrodes and data in the literature [27] confirmed that the potentials originate in the cortical tissue, and are relatively indifferent to retinal potentials.…”
Section: F-veps Investigationmentioning
confidence: 71%
“…Adult male offspring were anesthetized with sodium pentobarbital (50 mg/kg, ip), placed in a stereotaxic device, and the skull was exposed. Indwelling screw electrodes were implanted over primary visual cortex (1 mm anterior and 4 mm left of lambda) and a ground reference over the frontal cortex (2 mm anterior and 2 mm lateral left and right of bregma) according to procedures described previously (Herr et al, 1992, Boyes et al, 2003. The electrodes were constructed from stainless steel screws (00-90 × 1/16") soldered to Nichrome wires.…”
Section: Visual Evoked Potentialsmentioning
confidence: 99%
“…Linnoila et al 1974;Vasilescu 1976;Bulgheroni et al 1978;Vasilescu and Florescu 1980;Beauchamp Jr et al 1981;Clerici and Fechter 1991;Herr et al 1992). Histological and electrophysiological findings indicate the occurrence of primary axonal neuropathy (Linnoila et al 1974;Vasilescu 1976;Dyck and Thomas 1986;Dalvi 1988;Grasso 1988;Clerici and Fechter 1991) following exposure to CS 2 .…”
Section: Introductionmentioning
confidence: 99%