12th International Conference on Optical Fiber Sensors 1997
DOI: 10.1364/ofs.1997.pdp4
|View full text |Cite
|
Sign up to set email alerts
|

All Optical Fiber Sensor based on Optically Stimulated Luminescence for radiation detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2001
2001
2018
2018

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 1 publication
0
5
0
Order By: Relevance
“…To separate out the "stem effect" an identical fiber, but without a dosimeter attached, can be placed alongside the fiber with the dosimeter and, by assuming that the "stem effect" is the same in both fibers, the dosimeter RL signal can be obtained by subtraction (Fluehs et al, 1996). Roy et al (1997) designed a remote OSL dosimeter system based on rare earth doped alkaline earth sulphides (e.g. MgS) as the dosimeter material coupled to the end of an optical fiber and stimulated with an infra-red laser diode.…”
Section: The Measurement Of Rlmentioning
confidence: 99%
“…To separate out the "stem effect" an identical fiber, but without a dosimeter attached, can be placed alongside the fiber with the dosimeter and, by assuming that the "stem effect" is the same in both fibers, the dosimeter RL signal can be obtained by subtraction (Fluehs et al, 1996). Roy et al (1997) designed a remote OSL dosimeter system based on rare earth doped alkaline earth sulphides (e.g. MgS) as the dosimeter material coupled to the end of an optical fiber and stimulated with an infra-red laser diode.…”
Section: The Measurement Of Rlmentioning
confidence: 99%
“…Alkaline Earth sulfides doped with rare earth ions have also been demonstrated as effective dosimeters, measuring both dose and dose rate, based on OSL. The induced luminescence was determined and demonstrated good linearity for 40 μ Gy to 10 Gy, as can be seen in Figure 3 (Roy et al , 1997).…”
Section: Luminescence Dosimetersmentioning
confidence: 73%
“…Concerning radiation detection, these aluminiumcovered sensors can be applied to the monitoring of nuclear installations and particularly in areas out of reach for usual dosemeters. For example, a first generation sensor (2) is routinely inserted in small diameter pipes (typically 10 mm) both for real-time dose measurements and for remote accident detection (radioactive leakages). For radioprotection purposes, a compensation filter package can be developed with the help of the MCNP4b code for the quantity H*(10) (suitable for local dose measurement).…”
Section: Conclusion and Further Developmentsmentioning
confidence: 99%
“…On this assumption, a first radiation sensor based on rare-earth doped alkaline earth sulphides (AES) such as BaS, MgS or CaS (1) which can be stimulated with an infrared light, coupled with an optical fibre several kilometres long has been achieved. This instrument allows remote dose measurements from about 1 mGy up to several Gy (2) . However, such a device cannot be used for personal dosimetry for several reasons.…”
Section: Introductionmentioning
confidence: 99%