2000
DOI: 10.1258/0004563001899401
|View full text |Cite
|
Sign up to set email alerts
|

Aldosterone and renin measurements

Abstract: This article was prepared at the invitation of the Analytical Investigations Standing Committee of the Association of Clinical Biochemists.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
37
0

Year Published

2004
2004
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 63 publications
(39 citation statements)
references
References 88 publications
0
37
0
Order By: Relevance
“…Plasma renin activity is determined by adding exogenous AGT or TDP to a plasma sample and measuring Ang I formation by radioimmunoassay. 27,28 Sensitivity is a requirement of the renin assay because normal plasma renin activity concentrations are low and subnormal concentrations have diagnostic relevance. 27 Because of volume requirements of the classical methods and because of increasing use of mice in experimental studies, there was a need for more sensitive and specific ACE and renin assays.…”
Section: Discussionmentioning
confidence: 99%
“…Plasma renin activity is determined by adding exogenous AGT or TDP to a plasma sample and measuring Ang I formation by radioimmunoassay. 27,28 Sensitivity is a requirement of the renin assay because normal plasma renin activity concentrations are low and subnormal concentrations have diagnostic relevance. 27 Because of volume requirements of the classical methods and because of increasing use of mice in experimental studies, there was a need for more sensitive and specific ACE and renin assays.…”
Section: Discussionmentioning
confidence: 99%
“…Measurement of PRC instead of PRA may reduce some preanalytical and analytical problems and, therefore, improve intra-and interlaboratory reproducibility (23,24 ). Major advantages of the new PAC and PRC assays evaluated in our study include the ease and performance of the test (no cooling, a single plasma sample, and good interlaboratory reproducibility because the assays are automated) and the rapid availability of results (automated immunochemiluminometric assays), which is a prerequisite for extensive screening of hypertensive patients for PHA.…”
Section: Discussionmentioning
confidence: 99%
“…The stability of steroids including aldosterone in sera stored at Ϫ20°C or lower has been previously established. 27 …”
Section: Measurement Of Serum Aldosteronementioning
confidence: 99%