2019
DOI: 10.1007/s00445-018-1262-9
|View full text |Cite
|
Sign up to set email alerts
|

Airborne measurements of volcanic gas composition during unrest at Kuchinoerabujima volcano, Japan

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
17
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 14 publications
(17 citation statements)
references
References 46 publications
0
17
0
Order By: Relevance
“…This indicated a phreatic origin for the explosive activity [Mori et al 2016]. Similarly, during a period of unrest between 2014 and 2016 at Kuchinoerabujima volcano, Japan, airborne Multi-GAS measurements using UAS documented a decline in SO 2 /H 2 S molar ratio from 10 in December 2014 to 1.9 in March 2016 [Kazahaya et al 2019]. This gas ratio time-series reflected progressive conduit sealing and a return to a background degassing regime characterised by strong hydrothermal interaction [Kazahaya et al 2019].…”
Section: Supporting Monitoring During Unrest and Activitymentioning
confidence: 94%
See 4 more Smart Citations
“…This indicated a phreatic origin for the explosive activity [Mori et al 2016]. Similarly, during a period of unrest between 2014 and 2016 at Kuchinoerabujima volcano, Japan, airborne Multi-GAS measurements using UAS documented a decline in SO 2 /H 2 S molar ratio from 10 in December 2014 to 1.9 in March 2016 [Kazahaya et al 2019]. This gas ratio time-series reflected progressive conduit sealing and a return to a background degassing regime characterised by strong hydrothermal interaction [Kazahaya et al 2019].…”
Section: Supporting Monitoring During Unrest and Activitymentioning
confidence: 94%
“…In situ gas composition measurements can be carried out by miniaturised, pumped analyser systems for multiple gas species, which include electrochemical sensors for sulphur species (SO 2 and H 2 S) and non-dispersive infrared (NDIR) sensors for CO 2 and CH 4 [e.g. Di Kazahaya et al 2019;McGonigle et al 2008;Mori et al 2016;Rüdiger et al 2018;Shinohara 2013;Syahbana et al 2019]. Miniaturised mass spectrometer systems are also under development but their power requirements, and need for associated electronics and vacuum systems, results in instruments aimed at payload capabilities of either 3-5 kg or up to 20-50 kg for the full configuration .…”
Section: Gas Sensorsmentioning
confidence: 99%
See 3 more Smart Citations