2013
DOI: 10.1007/s12206-013-0872-6
|View full text |Cite
|
Sign up to set email alerts
|

Air to air fixed plate enthalpy heat exchanger, performance variation and energy analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2015
2015
2020
2020

Publication Types

Select...
5
2
1

Relationship

1
7

Authors

Journals

citations
Cited by 21 publications
(7 citation statements)
references
References 17 publications
0
6
0
Order By: Relevance
“…Past research found that membrane moisture transfer resistance varies when air flow inlet humidity conditions varies [8,9,[14][15][16][17][18][19][20][21][22][23][24][25][26]. The resistance variation across the membrane of the heat exchanger causes the amount of moisture transferred through the membrane to vary.…”
Section: Accepted Manuscriptmentioning
confidence: 99%
“…Past research found that membrane moisture transfer resistance varies when air flow inlet humidity conditions varies [8,9,[14][15][16][17][18][19][20][21][22][23][24][25][26]. The resistance variation across the membrane of the heat exchanger causes the amount of moisture transferred through the membrane to vary.…”
Section: Accepted Manuscriptmentioning
confidence: 99%
“…Al-Waked et al [1,8,9,15,16,26,27] performed detailed investigations on modelling and simulating heat and moisture transfer across porous membranes inside a Z-shape and other configurations heat exchangers. They simulated heat and moisture transfer across both constant and variable resistance membranes.…”
Section: Introductionmentioning
confidence: 99%
“…4 Numerous research works have been done on the application of energy recovery systems in the heating, ventilation and air conditioning (HVAC) system. [5][6][7][8] However, research on the performance of the stand-alone energy recovery system should be emphasised to increase the efficiency of the integrated energy recovery system with the HVAC system. Numerous studies using simulation tools have been conducted to assess energy recovery, but these studies were purely theoretical with little experimental validation.…”
Section: Introductionmentioning
confidence: 99%
“…Nasif et al carried out performance testing and energy analysis on a Z-type enthalpy heat exchanger in an air-conditioning system using the software HPRate. 6 Masitah et al performed heat transfer and effectiveness analyses for a cross-flow heat exchanger. 14 Zafirah and Mardiana studied the performance of an energy recovery system with changing operating parameters.…”
Section: Introductionmentioning
confidence: 99%