2013
DOI: 10.1080/14733315.2013.11684013
|View full text |Cite
|
Sign up to set email alerts
|

Air Stuffiness and Air Exchange Rate in French Schools and Day-Care Centres

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
38
0

Year Published

2015
2015
2020
2020

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 38 publications
(42 citation statements)
references
References 1 publication
3
38
0
Order By: Relevance
“…-1000 ppm: guideline value provided in the French regulation for non-residential buildings [16]; -1500 ppm: guideline value recommended for schools in the United Kingdom [40]; -2000 ppm: upper limit value for average CO 2 level observed in French schools during occupancy [33].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…-1000 ppm: guideline value provided in the French regulation for non-residential buildings [16]; -1500 ppm: guideline value recommended for schools in the United Kingdom [40]; -2000 ppm: upper limit value for average CO 2 level observed in French schools during occupancy [33].…”
Section: Discussionmentioning
confidence: 99%
“…The second set of data comes from a national survey conducted on 310 French nurseries (children aged 0e3 years), kindergartens (children aged 3e5 years) and elementary schools (children aged 6e10 years) carried out between September 2009 and July 2011 [32,33]. Corsica and overseas departments of R eunion Island and Martinique were also included in the survey.…”
Section: School Surveymentioning
confidence: 99%
“…Logue et al [7] suggested that PM 2.5 is one of the air pollutants which dominate health impacts in most U.S. residences Apart from those chemical toxicants and particulate matters, it is found that the CO 2 level may exceed 1500 ppm in classrooms in East London, which is much higher than the recommended level of 600 ppm from the Chartered Institution of Building Services Engineers (CIBSE) [33]. Ramalho et al [34] investigated the indoor CO 2 concentration in 489 mechanically ventilated classrooms in France, and the results indicated that 33% of the samples had a CO 2 concentration above 1700 ppm, which is two times greater than the CIBSE value.…”
Section: Introductionmentioning
confidence: 93%
“…Under that hypothesis, AER was determined using a simple mass balance equation and linear regression on log-transformed CO 2 concentrations (Ramalho et al, 2013). Each decay was taken into account only if it had more than 9 points (1h30 of decay) and if the determination coefficient of the linear regression was higher than 0.9.…”
Section: Measurement Of Ambient Parametersmentioning
confidence: 99%