2009
DOI: 10.1049/iet-rpg:20070091
|View full text |Cite
|
Sign up to set email alerts
|

Aggregate modelling of wind farms containing full-converter wind turbine generators with permanent magnet synchronous machines: transient stability studies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
68
0

Year Published

2011
2011
2018
2018

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 129 publications
(74 citation statements)
references
References 9 publications
1
68
0
Order By: Relevance
“…It has been demonstrated that the PMSG speed changes during voltage dips are negligible [6]. This is because the power supply to the DC circuit from the machine-side converter is approximately constant.…”
Section: Fig 3 Configuration Of a Pmsg Wind Generatorsmentioning
confidence: 99%
See 1 more Smart Citation
“…It has been demonstrated that the PMSG speed changes during voltage dips are negligible [6]. This is because the power supply to the DC circuit from the machine-side converter is approximately constant.…”
Section: Fig 3 Configuration Of a Pmsg Wind Generatorsmentioning
confidence: 99%
“…So the model of the PMSG and the machine-side converter, can be omitted. A constant DC power current source can be used to represent these instead (thus neglecting the machine side power fluctuations), and the simulation results at the PCC will not be greatly compromised [6].…”
Section: Fig 3 Configuration Of a Pmsg Wind Generatorsmentioning
confidence: 99%
“…Mandic [9] pointed that both the direct drive wind turbine and the gearbox-based drive train wind turbine had the problem of torsional deformations caused by the flexible mechanical coupling between the generator shaft and the turbine rotor. Refs [10] and [11] analyzed the effective shaft stiffness of the direct drive wind turbine. Although the stiffness of the shaft in the direct drive wind turbine is relative high compared to that in the gear-box based wind turbine with a longer shaft.…”
Section: Introductionmentioning
confidence: 99%
“…In [10], a popular way was mentioned that the damping rubber was mounted on the drive train shaft. The disadvantage of this way is costly and requires additional installation space on the drive train shaft.…”
Section: Introductionmentioning
confidence: 99%
“…Nowadays, WPP modeling for grid interconnection studies is an important issue, owing to the significant increase in grid-connected wind power capacity around the world [1,2]. WPPs can have tens to hundreds of WTGs, which is a large number when compared to conventional generation plants.…”
Section: Introductionmentioning
confidence: 99%