2012
DOI: 10.1109/tdei.2012.6396960
|View full text |Cite
|
Sign up to set email alerts
|

Ageing rate of paper insulation used in power transformers Part 2: Oil/paper system with medium and high oxygen concentration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
41
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
3
2
2

Relationship

0
7

Authors

Journals

citations
Cited by 79 publications
(43 citation statements)
references
References 5 publications
2
41
0
Order By: Relevance
“…The water content of Kraft and Grade 3 was measured during one aging test, at 100°C, high oxygen and 2.7% paper water content. A discussion on the comparison between Kraft paper, pressboard and the value provided by the Fessler equation was given in [2]. The measured water content of the pressboard, 2.6 %, was found to be very similar to its calculation, 2.7 %.…”
Section: Water Content Of Papermentioning
confidence: 70%
See 3 more Smart Citations
“…The water content of Kraft and Grade 3 was measured during one aging test, at 100°C, high oxygen and 2.7% paper water content. A discussion on the comparison between Kraft paper, pressboard and the value provided by the Fessler equation was given in [2]. The measured water content of the pressboard, 2.6 %, was found to be very similar to its calculation, 2.7 %.…”
Section: Water Content Of Papermentioning
confidence: 70%
“…This was performed by adding oxygen if the level of this gas became too low, or by removing the paper and conditioning to return its water content back to the desired value. This technique is fully described in [1,2].…”
Section: Investigation and Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…These diagnostic techniques include fault gas analysis, moisture analysis, dielectric monitoring, UHF sensors, acoustic sensors, off line or on line PD testing, dielectric response measurements, time response dielectric spectroscopy, dielectric discharge method and return voltage measurement, interpretation of measurements, transfer function analysis and expert system diagnostic software. The phenomenon of understanding the ageing of Kraft paper insulation shows that paper degradation is the cause of production of furan based aldehydes or hydrocarbon gases produced in mineral oil which results in change in DP (degree of polymerization) of cellulose in insulating paper or effect of various parameters using electrical, mechanical and chemical techniques is evaluated which are relevant to assess the state of both paper and oil insulation with identifying its effective life [5][6][7][8][9][10][11][12][13][14][15][16][17][18][19][20]. Thermal degradation of Kraft paper is caused due to increase in operating temperature so this insulating paper is thermally upgraded to neglect the aging by treating it with additional additives which result in formation of a new modified insulating paper such as amine modified Kraft paper, cyan ethylated paper, and carbamate modified paper by chemical modification for better performance and some other alternative oils are used as a substitute to mineral oil like alkyl-naphthalene oil, vegetable oil to increase the life of oil-paper insulation [21][22].…”
Section: Liquid Oil Insulation:-mentioning
confidence: 99%