2013
DOI: 10.1016/j.chemgeo.2013.02.021
|View full text |Cite
|
Sign up to set email alerts
|

Age intercalibration of 40Ar/39Ar sanidine and chemically distinct U/Pb zircon populations from the Alder Creek Rhyolite Quaternary geochronology standard

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

5
79
1
2

Year Published

2014
2014
2018
2018

Publication Types

Select...
9
1

Relationship

3
7

Authors

Journals

citations
Cited by 104 publications
(87 citation statements)
references
References 58 publications
5
79
1
2
Order By: Relevance
“…These latter eight age determinations were measured using older calibrations for the Fish Canyon Tuff sanidine (FCs) and Alder Creek Rhyolite sanidine (ACs) 2, 16, 24 . Several recent studies have indicated that the age of the Alder Creek Rhyolite sanidine is ~1.185–1.186 Ma (refs 3032). Thus, we have recalculated the eight published ages using recent standard age calibrations (i.e.…”
Section: Methodsmentioning
confidence: 99%
“…These latter eight age determinations were measured using older calibrations for the Fish Canyon Tuff sanidine (FCs) and Alder Creek Rhyolite sanidine (ACs) 2, 16, 24 . Several recent studies have indicated that the age of the Alder Creek Rhyolite sanidine is ~1.185–1.186 Ma (refs 3032). Thus, we have recalculated the eight published ages using recent standard age calibrations (i.e.…”
Section: Methodsmentioning
confidence: 99%
“…U-Pb geochronology and trace element analysis by LA-ICPMS followed the methods described in Rivera et al (2013) using a ThermoElectron X-Series II quadrupole ICPMS and a New Wave Research UP-213 Nd:YAG UV (213 nm) laser ablation system. In-house analytical protocols, standard materials, and data reduction software were used for acquisition and calibration of U-Pb dates and a suite of high field strength elements (HFSE) and rare earth elements (REE).…”
Section: Datingmentioning
confidence: 99%
“…Ab lated ma te rial was car ried by a 1.2 L/min He gas stream to the 0.8 L/min nebulizer flow of the plasma. Specific analyte dwell times, back ground sub trac tion, el e men tal and iso to pic cal i bra tion meth ods, and er ror prop a ga tion al gorithms are de scribed in Rivera et al (2013). Quoted un cer tainties on the iso to pic ra tios and dates in the data ta ble are based upon an a lyt i cal count ing sta tis tics for the pur pose of intercomparison of dates in our screen ing study.…”
Section: Methodsmentioning
confidence: 99%