2002
DOI: 10.1117/12.473478
|View full text |Cite
|
Sign up to set email alerts
|

Advances in process overlay: ATHENA alignment system performance on critical process layers

Abstract: The continuing reduction of IC device dimensions puts stringent demands on the corresponding overlay performance. As part of the total overlay budget, the effects of the different process parameters need to be characterized and well understood. In a joint development program between IMEC and ASML, the robustness of different alignment strategies to process parameters has been evaluated using the ATHENA alignment system. This paper looks at both Front-end (Shallow Trench Isolation) and Back-end (W-CMP and copp… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2003
2003
2005
2005

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 9 publications
(8 citation statements)
references
References 4 publications
0
8
0
Order By: Relevance
“…For example, when fifth order enhanced mark is under evaluation, fifth order detector will be used. This practice has also been applied in the previous reported work in evaluation of alignment mark using ATHENA system [2][3][4][5] . We only focused in the evaluation of 5 th order SPM, 5 th order NSPM and 7 th order NSPM.…”
Section: Methodsmentioning
confidence: 92%
“…For example, when fifth order enhanced mark is under evaluation, fifth order detector will be used. This practice has also been applied in the previous reported work in evaluation of alignment mark using ATHENA system [2][3][4][5] . We only focused in the evaluation of 5 th order SPM, 5 th order NSPM and 7 th order NSPM.…”
Section: Methodsmentioning
confidence: 92%
“…Several other W-CMP / Al-PVD flows [6] have been investigated as well. The results for three alternative process flows (thick Al, thick W, thin oxide layer) of 2 wafers each are shown in Fig.…”
Section: Predictive Recipes On Vspmsmentioning
confidence: 99%
“…We investigated a W-CMP / Al-PVD process flow for which all three gratings of the VSPM are underfilled [6]. The Alignment Advisor is used to measure the W-CMP / Al-PVD processed marks in a grid determined by a set of ideal non-processed marks [4].…”
Section: Predictive Recipes On Vspmsmentioning
confidence: 99%
“…It is noted here that these CMP effects to signal strength variation are only attributed to the difference in planarity of the Si wafer, and the polished layer(s) on top of this wafer. Control of alignment signal strength, and thus of alignment mark phase depth, is considered a main improvement possibility for overlay control [5,6,7]. A means to stabilize signal strength is to minimize the number of CMP steps involved for the copper floating marks.…”
Section: Figure 2 Cmp Transfer Function (Left) and Calculated A Substmentioning