1984
DOI: 10.1016/s0003-2670(00)84241-5
|View full text |Cite
|
Sign up to set email alerts
|

Adsorptive stripping voltammetry of electroactive organic compounds

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
23
0

Year Published

1987
1987
2017
2017

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 74 publications
(24 citation statements)
references
References 15 publications
1
23
0
Order By: Relevance
“…On the other hand, the dependence of LS-AdASV peak current magnitudes of bly owing to an inhibition of the voltammetric process occurring after saturation of carbon [27] or interactions among the molecules in the adsorbed state become noticeable [28]. This could be explained by the release of an amount of the adsorbed molecules due to possible repulsive interaction between the adsorbed species when coverage of the electrode has been reached [28].…”
Section: Linear Sweep Stripping Voltammetry Methodsmentioning
confidence: 99%
“…On the other hand, the dependence of LS-AdASV peak current magnitudes of bly owing to an inhibition of the voltammetric process occurring after saturation of carbon [27] or interactions among the molecules in the adsorbed state become noticeable [28]. This could be explained by the release of an amount of the adsorbed molecules due to possible repulsive interaction between the adsorbed species when coverage of the electrode has been reached [28].…”
Section: Linear Sweep Stripping Voltammetry Methodsmentioning
confidence: 99%
“…It is ascribed to the reduction of complex of Hg II and DA according to the literature. 8,9 After addition of Al III (Fig. 1c), a new sharp peak appears at -900 mV; that the height of the peak is proportional to the DA concentration was observed in further study.…”
Section: Resultsmentioning
confidence: 53%
“…The electrochemical behaviors of DA on various kinds of electrodes, including gold electrode, carbon fiber microelectrodes, glassy carbon electrodes, carbon paste electrode and hanging mercury drop electrode (HMDE), have been investigated extensively in the last two decades. [3][4][5][6][7][8][9] However, a series of biomolecules possessing similar structures and characters such as epinephrine (EP) and norepinephrine (NE), coexist with DA in biosystems, making their determination and recognition quite difficult. In addition, a high concentration of ascorbic acid in a biosystem greatly disturbs the anodic responses of DA.…”
Section: Introductionmentioning
confidence: 99%
“…The method of adsorptive stripping analysis , both of adsorbable complexes and of electroactive organic ccirounds , appears very pranising , as it broadens the range of trace analysis down to concentrations below 1 Ig/Kg (ref. 44).…”
Section: Discussionmentioning
confidence: 99%