2003
DOI: 10.1016/s0043-1354(02)00265-8
|View full text |Cite
|
Sign up to set email alerts
|

Adsorption of cobalt from aqueous solutions onto sepiolite

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

10
170
1
2

Year Published

2007
2007
2018
2018

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 438 publications
(186 citation statements)
references
References 20 publications
10
170
1
2
Order By: Relevance
“…Values of the enthalpy changes (∆H), always negative, are indicative of an exothermic process, and their magnitudes (<40 kJ/mol) show the adsorption of phenol on β-CD polymer within the range investigations in this study to be a physical adsorption in nature. 36 The positive entropy changes (∆S) indicated that the degrees of freedom increased at the solid-liquid interface during the adsorption. The obtained Gibbs free energy changes (∆G) are negative at all of the tested temperatures range from 15 to 60 o C, confirming that the adsorption of phenol on β-CD polymer is spontaneous and thermodynamically favorable.…”
Section: Resultsmentioning
confidence: 99%
“…Values of the enthalpy changes (∆H), always negative, are indicative of an exothermic process, and their magnitudes (<40 kJ/mol) show the adsorption of phenol on β-CD polymer within the range investigations in this study to be a physical adsorption in nature. 36 The positive entropy changes (∆S) indicated that the degrees of freedom increased at the solid-liquid interface during the adsorption. The obtained Gibbs free energy changes (∆G) are negative at all of the tested temperatures range from 15 to 60 o C, confirming that the adsorption of phenol on β-CD polymer is spontaneous and thermodynamically favorable.…”
Section: Resultsmentioning
confidence: 99%
“…6). All the H 0 values, −36.87, −28.39, and −37.24 kJ mol −1 , were less than 40 kJ mol −1 thereby implying that the sorption of atrazine onto MWCNTs is mainly a physisorption process [38,39]. The negative S 0 indicated decreased randomness at the solid-liquid interface during sorption of atrazine.…”
Section: Thermodynamic Analysismentioning
confidence: 93%
“…The Frendlich isotherm appeared to be linear within the whole concentration range with high correlation coefficient, which certified that the Frendlich isotherm could excellently describe the monolayer adsorption processes when the equilibrium adsorption amount (q max ) and adsorption constant (k) were found to increase with the increase of temperature. Thermodynamic evaluation of adsorption process the type of adsorption can be determined through thermodynamic quantities as ∆H ads and ∆S [31] . The adsorption process is composed of two contributions, i.e., enthalpic and entropic, which characterize whether the reaction is spontaneous or not.…”
Section: Adsorption Isothermsmentioning
confidence: 99%