2021
DOI: 10.1016/j.jmbbm.2021.104648
|View full text |Cite
|
Sign up to set email alerts
|

Adhesion as a component of retention force of overdenture prostheses-study on selected Au based dental materials used for telescopic crowns using atomic force microscopy and contact angle techniques

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 20 publications
0
5
0
Order By: Relevance
“…Telescopic crowns were used as retainers for removable partial dentures in the early phase. Dabrowa et al [ 9 ] mentioned in their study that telescopic crowns which are found in patients with residual and reduced dentition provide anchorage on single abutments and direct the occlusal forces on the long axis of the abutment teeth which in turn aids in longer retention in the alveolar bone. A recent addition to the array of unsplinted attachment systems is the telescopic attachments.…”
Section: Discussionmentioning
confidence: 99%
“…Telescopic crowns were used as retainers for removable partial dentures in the early phase. Dabrowa et al [ 9 ] mentioned in their study that telescopic crowns which are found in patients with residual and reduced dentition provide anchorage on single abutments and direct the occlusal forces on the long axis of the abutment teeth which in turn aids in longer retention in the alveolar bone. A recent addition to the array of unsplinted attachment systems is the telescopic attachments.…”
Section: Discussionmentioning
confidence: 99%
“…The contact angle on both sides of the droplet was measured by a CCD camera, and after digital image analysis, the average contact angle was determined using Young-Laplace method. Each measurement was repeated 20 times [42][43][44][45].…”
Section: Methodsmentioning
confidence: 99%
“…Water and diiodomethane were used as reference liquids to characterize the wettability of the coating surface, and their SFE parameters are shown in Table S1. The CA measurements were conducted on a contact angle system (DSA100, KRUSS, Germany) at 25 °C. , Water or diiodomethane (2 μL) was placed on the surface of the coatings using a syringe. Five points on each coating were measured to obtain an average value.…”
Section: Experimental Sectionmentioning
confidence: 99%
“…The CA measurements were conducted on a contact angle system (DSA100, KRUSS, Germany) at 25 °C. 37,38 Water or diiodomethane (2 μL) was placed on the surface of the coatings using a syringe. Five points on each coating were measured to obtain an average value.…”
Section: ■ Experimental Sectionmentioning
confidence: 99%