Additional Certified Values for CCRMP Soils SO‐1 to ‐4

Abstract: New mean values for up to 11 major and minor and up to 11 trace elements in soils SO‐1 to SO4 have been calculated by two procedures. Analytical results received by CCRMP subsequent to the certification program of 1979 were included. In one instance, the same procedure as used for certification wherein all results except those rejected on chemical and/or statistical considerations was followed, but little improvement over the 1979 calculations was obtained. The other procedure is proposed by the authors for us… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0
1

Year Published

1989
1989
2022
2022

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 3 publications
0
3
0
1
Order By: Relevance
“…0.75 i 0.07 ( 2 4 ) 0.76 i 0.08 (12) 0.75 i 0.05 (5) 0.75 (1) 0.69 t 0.06 (5) 0.80 (2) 0.90 (1) 0.98 t 0.10 (23) 0.99 t 0.14 (12) 0.99 t 0.03 ( 4 ) 0.99 ( 1 ) 0.94 t 0.16 ( 5 ) 0.98 ( 2 ) 0.95 ( 1 )…”
Section: (1)unclassified
See 1 more Smart Citation
“…0.75 i 0.07 ( 2 4 ) 0.76 i 0.08 (12) 0.75 i 0.05 (5) 0.75 (1) 0.69 t 0.06 (5) 0.80 (2) 0.90 (1) 0.98 t 0.10 (23) 0.99 t 0.14 (12) 0.99 t 0.03 ( 4 ) 0.99 ( 1 ) 0.94 t 0.16 ( 5 ) 0.98 ( 2 ) 0.95 ( 1 )…”
Section: (1)unclassified
“…IJnccrtilied information was given for up to 49 othcr constituents (2)(3). Rcvised certified values on the original suite of elcmcnts, and new certified values for up to 24 elements not previously certified, have subsequently been provided (4).…”
mentioning
confidence: 99%
“…Elemental composition of the rock and sediment samples (fine‐grinded powder in Chemplex SpectroMicro ® Sample Cups 3110) and the invertebrate samples (felt‐like aggregates in Chemplex SpectroMicro ® Sample Cups 3110 with 3 μm‐thick Prolene films) was assayed by energy dispersive X‐ray fluorescence (EDXRF) analysis using a Spectro XEPOS Plus spectrometer and calibration models based on the fundamental parameter methods (Tessadri, ). The experimental parameters were obtained by calibration of the whole system by means of the CCRMP reference soils SO‐1, SO‐2, SO‐3, and SO‐4 (Steger, Bowman, & McKeague, ). Results obtained on five replicate samples demonstrate that the relative standard deviation on the metal assay is better than ±10%.…”
Section: Methodsmentioning
confidence: 99%
“…using a Spectro XEPOS Plus spectrometer and calibration models based on the fundamental parameter methods (Tessadri, 2003). The experimental parameters were obtained by calibration of the whole system by means of the CCRMP reference soils SO-1, SO-2, SO-3, and SO-4 (Steger, Bowman, & McKeague, 1985). Results obtained on five replicate samples demonstrate that the relative standard deviation on the metal assay is better than AE10%.…”
Section: Catchment Bedrock Lake Sediments and Invertebratesmentioning
confidence: 99%