Adaptive setting of distance relay for MOV-protected series compensated line considering wind power

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
6
0
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 9 publications
0
6
0
1
Order By: Relevance
“…Providing adaptive distance protection settings to protect series compensated TLs connected with wind power is proposed in [24], depending on synchronized voltage and current measurements at both local and remote ends. Besides, the voltage measurements across the compensator and the current through it are also measured to estimate its impedance continuously during fault, which is considered the main drawback.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…Providing adaptive distance protection settings to protect series compensated TLs connected with wind power is proposed in [24], depending on synchronized voltage and current measurements at both local and remote ends. Besides, the voltage measurements across the compensator and the current through it are also measured to estimate its impedance continuously during fault, which is considered the main drawback.…”
Section: Introductionmentioning
confidence: 99%
“…Besides, the voltage measurements across the compensator and the current through it are also measured to estimate its impedance continuously during fault, which is considered the main drawback. In addition, the impact of ground fault resistance variations on the performance of proposed adaptive distance relay setting is not studied in [24].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…However, the economic feasibility and complexity of these technologies must be considered when designing and selecting such schemes. The schemes in [16] and [17] provide an adaptive setting for conventional distance relays considering the effects of impedance variation due to MOV operation. However, these schemes still need the pre-definition of the fault section.…”
Section: Introductionmentioning
confidence: 99%
“…Metal Oxide Varistor ) na linha de transmissão em estudo.Os bancos de capacitores em série atuam em uma linha de transmissão reduzindo sua reatância série, aumentando assim a capacidade de fluxo de potência passante nessa linha. Os benefícios desse uso incluem redução de problemas relacionadosà estabilidade de tensão, redução de perdas e interrupção do fornecimento de energia como discutido emSivov et al (2016).O MOV, a partir do varistor, atua contra sobretensões sobre o capacitor série segundoSivov et al (2016). O reator de amortecimento limita correntes de descarga do capacitor queé resultante do fechamento do gap de ar ou do disjuntor em derivação.…”
unclassified