2015
DOI: 10.1016/j.talanta.2015.07.008
|View full text |Cite
|
Sign up to set email alerts
|

Acetylcholinesterase biosensor for inhibitor measurements based on glassy carbon electrode modified with carbon black and pillar[5]arene

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 52 publications
(14 citation statements)
references
References 56 publications
0
12
0
Order By: Relevance
“…Addition of Ag + and Cu 2+ ions generated AgNPs and Cu 2 O particles, respectively. The group prepared an AChE biosensor from their GCE incorporating 2 by treating it with N ‐(3‐dimethylaminopropyl)‐ N ′‐ethylcarbodiimide chloride followed by N ‐hydroxysuccinimide and finally AChE in phosphate buffered saline . The addition of the pillar[5]arene gave an enhanced electrode response to sub‐nanomolar concentrations of the anticholinesterase pesticides malaoxon, methylparaoxon, carbofuran and aldicarb over five orders of magnitude.…”
Section: Pillar[n]arenes For Detectionmentioning
confidence: 99%
“…Addition of Ag + and Cu 2+ ions generated AgNPs and Cu 2 O particles, respectively. The group prepared an AChE biosensor from their GCE incorporating 2 by treating it with N ‐(3‐dimethylaminopropyl)‐ N ′‐ethylcarbodiimide chloride followed by N ‐hydroxysuccinimide and finally AChE in phosphate buffered saline . The addition of the pillar[5]arene gave an enhanced electrode response to sub‐nanomolar concentrations of the anticholinesterase pesticides malaoxon, methylparaoxon, carbofuran and aldicarb over five orders of magnitude.…”
Section: Pillar[n]arenes For Detectionmentioning
confidence: 99%
“…The principle of AChE reactivation by PBS is not understood at this moment and corresponding mechanism needs further investigation. [35][36][37][38] For each test accuracy, the biosensor was allowed to rest in the PBS environment for a period of time aer undergoing OPs inhibition until the catalytic performance is fully reactivated. Aer the biosensor was inhibited by immersion in DDVP, it can be reactivated by being soaked in PBS.…”
Section: Resultsmentioning
confidence: 99%
“…Because the host was immobilized on the surface of magnetic nanoparticles, pesticide binding was followed by effective magnetic-based pesticide removal (Figure 9B). In another example, electrochemical-based detection of the binding of pesticides to a pillararenes was reported with extremely high sensitivity (Shamagsumova et al, 2015;Hou et al, 2019).…”
Section: Pillararenesmentioning
confidence: 99%