2011
DOI: 10.1016/j.snb.2011.09.059
|View full text |Cite
|
Sign up to set email alerts
|

Acetylcholinesterase biosensor based on 3-carboxyphenylboronic acid/reduced graphene oxide–gold nanocomposites modified electrode for amperometric detection of organophosphorus and carbamate pesticides

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
70
1
2

Year Published

2013
2013
2024
2024

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 177 publications
(76 citation statements)
references
References 49 publications
3
70
1
2
Order By: Relevance
“…10-100 0.1 ng/mL [39] BSA/anti-chlorpyrifos/AuNPs/PANI/MWCNTs/GCE 0.1-40 40-500 0.06 ng/mL This work 6.1659lgC (10 −6 mg/mL) and %ΔI=-22.436+27.235lgC (10 −6 mg/mL), with the correlation coefficients of 0.9913 and 0.9904, respectively. The detection limit was estimated to be 0.06×10 −6 mg/mL at a signal/noise of 3 (S/N=3) between the detection signal of low concentration samples and the noise of blank samples.…”
Section: Amperometric Response Of the Immunosensor To Chlorpyrifos Comentioning
confidence: 80%
“…10-100 0.1 ng/mL [39] BSA/anti-chlorpyrifos/AuNPs/PANI/MWCNTs/GCE 0.1-40 40-500 0.06 ng/mL This work 6.1659lgC (10 −6 mg/mL) and %ΔI=-22.436+27.235lgC (10 −6 mg/mL), with the correlation coefficients of 0.9913 and 0.9904, respectively. The detection limit was estimated to be 0.06×10 −6 mg/mL at a signal/noise of 3 (S/N=3) between the detection signal of low concentration samples and the noise of blank samples.…”
Section: Amperometric Response Of the Immunosensor To Chlorpyrifos Comentioning
confidence: 80%
“…Parameters affecting the biosensor response such as pH, applied potential, enzyme loading and inhibition time were optimized. Moreover, this biosensor had good repeatability and high stability [10].…”
Section: Hydrolysis Of Acetylcholinementioning
confidence: 94%
“…These organic toxins enter animal and human bodies directly or indirectly through the food chain or drinking water, and threat human health by inhibiting acetylcholinesterase which is essential for the function of the central nervous system in humans. So it is of great significance to develop a fast, reliable, economical and analytical method for determination of trace amounts of these pesticides [1].…”
Section: Introductionmentioning
confidence: 99%
“…In addition to the already mentioned limitations encountered in chromatography techniques, the other problem related to the activity of the acetylcholinesterase, which is irreversibly inhibited by organo-phosphorous compounds. Electrochemical analytical techniques, based on chemically modified sensors have proved to be a sensitive and selective process for the determination of organo-phosphorous compounds (Cao et al, 2015;Kumaravel and Chandrasekaran, 2015;Liu et al, 2011;Mulchandani et al, 2001a,b;Mulchandani et al, 1999).…”
Section: Introductionmentioning
confidence: 99%