2015
DOI: 10.1016/j.apm.2014.12.035
|View full text |Cite
|
Sign up to set email alerts
|

Accurate finite volume investigation of nanofluid mixed convection in two-sided lid driven cavity including discrete heat sources

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
18
0

Year Published

2016
2016
2019
2019

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 52 publications
(20 citation statements)
references
References 37 publications
2
18
0
Order By: Relevance
“…Results obtained are in excellent agreement with those of [8,49,50,51,52,53]. Grid independent solution for the problem is achieved through grid refinement study and results for average Nusselt number has been given in Table 3 for Re = 100, Ri = 20, φ = 0.2, Ha = 50, γ = 15 • .…”
Section: Code Validation and Grid Independence Testsupporting
confidence: 72%
See 1 more Smart Citation
“…Results obtained are in excellent agreement with those of [8,49,50,51,52,53]. Grid independent solution for the problem is achieved through grid refinement study and results for average Nusselt number has been given in Table 3 for Re = 100, Ri = 20, φ = 0.2, Ha = 50, γ = 15 • .…”
Section: Code Validation and Grid Independence Testsupporting
confidence: 72%
“…They found that Richardson number and the moving parameter play a dominant role in the transfer of heat and mass and other flow characteristics within a cavity. More studies on mixed convection in cavity can be found in [5,6,7,8,9,10].…”
Section: Introductionmentioning
confidence: 99%
“…The e ective density at the reference temperature, thermal di usivity, the heat capacitance, and the thermal expansion coe cient of the nano uid based on classical models can be written as follows [9]:…”
Section: Mathematical Modellingmentioning
confidence: 99%
“…They found that the external magnetic eld has a tendency to slow down the convection ow within the enclosure. Moumni et al [9] utilized an accurate nite volume method to study Cu, Ag, Al 2 O 3 , and TiO 2 -water nano uids in a two-sided liddriven cavity including discrete heat sources. Results indicate that the nanoparticles with larger thermal conductivity usually cause larger enhancement in heat transfer rate of nano uid.…”
Section: Introductionmentioning
confidence: 99%
“…They found that Richardson number and solid volume fraction affect the fluid flow and heat transfer in the cavity. Moumni et al [14] studied the nanofluid mixed convection in two-sided lid driven cavity including discrete heat Sources by using the finite volume method. The results showed that by increasing Richardson and Reynolds numbers and the solid volume fraction, the heat transfer rate increases.…”
Section: Introductionmentioning
confidence: 99%