Accuracy of reverse‐transcription polymerase chain reaction and loop‐mediated isothermal amplification in diagnosing severe fever with thrombocytopenia syndrome: A systematic review and meta‐analysis

Abstract: Nucleic acid molecular diagnostic technology plays an important role in the detection of severe fever with thrombocytopenia syndrome (SFTS). However, no relevant reports have been published on the accuracy of reverse-transcription polymerase chain reaction (RT-PCR) and reverse-transcription loop-mediated isothermal amplification (RT-LAMP) in the diagnosis of SFTS. Thus, we conducted a meta-analysis and systematic review to evaluate the accuracy of the two methods.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 46 publications
0
3
0
Order By: Relevance
“…17 Previous studies have evaluated the detection of SFTS using reverse transcription LAMP (RT-LAMP) and reported the sensitivity of 84.9%-99% [16][17][18][19] and specificity as high as approximately 99% (95% confidence interval: 0.93-1.00). 20 These studies suggest that RT-LAMP as a viable detection method with a wide range of clinical applications. However, in clinical practice, the relationship between the application procedures of RT-LAMP in the disease process has not been evaluated, and results of RT-LAMP have not been compared among samples collected from patients during different periods.…”
Section: Several Methods Have Been Developed For the Diagnosis Of Sftsmentioning
confidence: 95%
See 1 more Smart Citation
“…17 Previous studies have evaluated the detection of SFTS using reverse transcription LAMP (RT-LAMP) and reported the sensitivity of 84.9%-99% [16][17][18][19] and specificity as high as approximately 99% (95% confidence interval: 0.93-1.00). 20 These studies suggest that RT-LAMP as a viable detection method with a wide range of clinical applications. However, in clinical practice, the relationship between the application procedures of RT-LAMP in the disease process has not been evaluated, and results of RT-LAMP have not been compared among samples collected from patients during different periods.…”
Section: Several Methods Have Been Developed For the Diagnosis Of Sftsmentioning
confidence: 95%
“…The results of LAMP can be determined by observing the change in the color of mixture with the naked eye, eliminating the need for highly trained technicians 17 . Previous studies have evaluated the detection of SFTS using reverse transcription LAMP (RT‐LAMP) and reported the sensitivity of 84.9%–99% 16–19 and specificity as high as approximately 99% (95% confidence interval: 0.93–1.00) 20 …”
Section: Introductionmentioning
confidence: 99%
“…Detection of SFTSV genome could be achieved by different nucleic acid detection techniques such as RT-PCR (13,(40)(41)(42)(43), real-time RT-PCR (23,28,41,(44)(45)(46)(47)(48), LAMP (24,(49)(50), as well as RPA (25,(51)(52).…”
Section: Nucleic Acid Detectionmentioning
confidence: 99%