2012
DOI: 10.1227/neu.0b013e3182320bd6
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy of Magnetic Resonance Imaging–Directed Frame-Based Stereotaxis

Abstract: Stylette positions did deviate from the plan, albeit by 1.4 mm in the axial plane and 1.8 mm in 3-dimensional space. There was no difference between the accuracies at the dura and the target approximately 70 mm deep in the brain, suggesting potential feasibility for accurate planning along the whole trajectory.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
19
0

Year Published

2013
2013
2018
2018

Publication Types

Select...
8

Relationship

4
4

Authors

Journals

citations
Cited by 14 publications
(19 citation statements)
references
References 37 publications
0
19
0
Order By: Relevance
“…These systems can be classified into 3 groups, the frame-based, the frameless and the iMRI-guided systems. The frame-based systems include the Leksell system (Elekta Instruments Inc., Sweden) [18,31,41], the Zamorano-Dujovny system (Stryker-Leibinger Inc., Germany) [19], the Riechert-Mundinger system (Innomed Pte Ltd., Germany) [20], the Cosman-Roberts-Wells system (Radionics Inc., USA) [17,39,42] and the Neuromate robot (Renishaw Inc., UK) [43]. The frameless systems include NexFrame (Image-Guided Neurologics Inc., USA) [21,26,32] and the STarFix microTargeting Platform (FHC Inc., USA) [22,27,44].…”
Section: Resultsmentioning
confidence: 99%
“…These systems can be classified into 3 groups, the frame-based, the frameless and the iMRI-guided systems. The frame-based systems include the Leksell system (Elekta Instruments Inc., Sweden) [18,31,41], the Zamorano-Dujovny system (Stryker-Leibinger Inc., Germany) [19], the Riechert-Mundinger system (Innomed Pte Ltd., Germany) [20], the Cosman-Roberts-Wells system (Radionics Inc., USA) [17,39,42] and the Neuromate robot (Renishaw Inc., UK) [43]. The frameless systems include NexFrame (Image-Guided Neurologics Inc., USA) [21,26,32] and the STarFix microTargeting Platform (FHC Inc., USA) [22,27,44].…”
Section: Resultsmentioning
confidence: 99%
“…The PSA was targeted bilaterally under general anesthesia, using the MRI-directed implantable guide tube technique as a staged procedure. 6,9 Carbothane proxy markers of electrode position (NeuroGuide, Renishaw Plc) were placed stereotactically to the cZI targets, and a 3-T intraoperative MRI study was performed after administration of a second general anesthetic agent. Once position was confirmed at the posteromedial border of the STN (Fig.…”
Section: Operationmentioning
confidence: 99%
“…While the definition of target structures may be improved with increased MRI field strengths, image-guided lead placement could conversely suffer due to limiting factors that are also in turn proportionate to the strength of the magnetic field. For example, as the magnet strength increases, so do the image distortions caused by magnetic field inhomogeneities and gradient field nonlinearities [10,11,12,13]. Moreover, image distortion also results from differences in magnetic susceptibility between brain tissues and foreign objects, and these distortions are likewise larger with a higher magnetic field strength.…”
Section: Introductionmentioning
confidence: 99%