Accuracy of continuous glucose monitoring in preterm infants: a systematic review and meta-analysis

Abstract: Background and objectivesContinuous glucose monitoring (CGM) could be a valuable instrument for measurement of glucose concentration in preterm neonate. We undertook a systematic review and meta-analysis to compare the diagnostic accuracy of CGM devices to intermittent blood glucose evaluation methods for the detection of hypoglycaemic or hypoglycaemic events in preterm infants.Data sourcesA structured electronic database search was performed for studies that assessed the accuracy of CGM against any intermitte… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 9 publications
(7 citation statements)
references
References 42 publications
0
7
0
Order By: Relevance
“…The quality of the RCTs included in this review was assessed by the GRADE system [ 35 ]. GRADE clearly differentiates the quality of each RCT from the overall strength of the evidence, making the accuracy of the analysis results clearer [ 71 , 72 ]. Grading the strength of the evidence using the GRADE approach is becoming an important, recommended step in a comprehensive evidence evaluation and could increase the transparency of the clinical decision-making processes, especially when the quality of the evidence is poor or unclear [ 71 , 73 ].…”
Section: Discussionmentioning
confidence: 99%
“…The quality of the RCTs included in this review was assessed by the GRADE system [ 35 ]. GRADE clearly differentiates the quality of each RCT from the overall strength of the evidence, making the accuracy of the analysis results clearer [ 71 , 72 ]. Grading the strength of the evidence using the GRADE approach is becoming an important, recommended step in a comprehensive evidence evaluation and could increase the transparency of the clinical decision-making processes, especially when the quality of the evidence is poor or unclear [ 71 , 73 ].…”
Section: Discussionmentioning
confidence: 99%
“…Furthermore, of the neonates who did develop hypoglycaemia (BG < 2.6 mmol/L, 47 mg/dl) 25% spent at least 5 h with SG < 2.6 mmol/L (47 mg/dl), and nearly a quarter of neonates who were considered to have normal BG levels by routine monitoring had episodes of clinically silent hypoglycaemia. Developments however are needed to provide diagnostic accuracy at the thresholds for hypoglycaemia in neonates which are significantly lower than those used in adults, to provide confidence in their use at this time ( 34 ). The potential to support proactive monitoring of such at-risk neonates to prevent hypoglycaemia vs. the potential to increase unnecessary interventions and maternal and neonate separation requires further evaluation.…”
Section: What Types Of Neonates May Benefit?mentioning
confidence: 99%
“…The MARD score for hypoglycaemic values (2.8–3.9 mmol/L, 50–70 mg/dl) is often higher than in euglycaemic values in patients with diabetes ( 48 , 49 ). A recent systematic review concluded that the sensitivity of CGM for detecting hypoglycaemia was low ( 34 ). This may partly be due to the increased rate of change during episodes of hypoglycaemia.…”
Section: What Are the Device Limitations For Use In The Neonate?mentioning
confidence: 99%
“…(1) Methods of synthesis are simple and inexpensive (2) Rough surface enhances the mobility of analyte (3) Layers can be effectively tailored to intercalate preferred anions (4) Provide surfaces where enzymes can maintain their activity (5) Allow for easy loading of catalysts (6) Surfaces can be used to immobilize some modifiers or biomolecules.…”
Section: Ldhmentioning
confidence: 99%
“…They used a bivariate model to summarize the receiver operating characteristic curve (ROC) curve and extract the area under the curve (AUC). According to their findings, CGM systems have low sensitivity for detecting hypoglycemia in preterm newborns but good accuracy for identifying hyperglycemia [ 4 ]. As a result, new approaches are continually being developed, and minimally invasive glucose monitoring technologies have sparked a lot of interest in this field.…”
Section: Introductionmentioning
confidence: 99%