2021
DOI: 10.1016/j.ajodo.2021.04.020
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy of 3-dimensional stereophotogrammetry: Comparison of the 3dMD and Bellus3D facial scanning systems with one another and with direct anthropometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
25
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 22 publications
(31 citation statements)
references
References 25 publications
2
25
0
Order By: Relevance
“…Table 2 shows the risk of bias and application concerns according to the QUADAS-2 guidelines. Among 23 articles [ 39 , 40 , 41 , 42 , 43 , 44 , 45 , 46 , 47 , 48 , 49 , 50 , 51 , 52 , 53 , 54 , 55 , 56 , 57 , 58 , 59 , 60 , 61 ], 14 papers showed an overall low risk of bias [ 40 , 41 , 43 , 45 , 46 , 47 , 48 , 49 , 50 , 51 , 53 , 56 , 59 , 60 , 61 ], 3 articles had unclear risk of bias [ 39 , 44 , 52 , 57 ] and 4 articles displayed a high risk of bias [ 42 , 54 , 55 , 58 ]. Concerning applicability concerns, all articles showed an overall low level of concern, however, the domain “index test” showed more frequently an unclear concern because some papers did not sufficiently describe the scanning procedures and the used devices [ 40 ,…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Table 2 shows the risk of bias and application concerns according to the QUADAS-2 guidelines. Among 23 articles [ 39 , 40 , 41 , 42 , 43 , 44 , 45 , 46 , 47 , 48 , 49 , 50 , 51 , 52 , 53 , 54 , 55 , 56 , 57 , 58 , 59 , 60 , 61 ], 14 papers showed an overall low risk of bias [ 40 , 41 , 43 , 45 , 46 , 47 , 48 , 49 , 50 , 51 , 53 , 56 , 59 , 60 , 61 ], 3 articles had unclear risk of bias [ 39 , 44 , 52 , 57 ] and 4 articles displayed a high risk of bias [ 42 , 54 , 55 , 58 ]. Concerning applicability concerns, all articles showed an overall low level of concern, however, the domain “index test” showed more frequently an unclear concern because some papers did not sufficiently describe the scanning procedures and the used devices [ 40 ,…”
Section: Resultsmentioning
confidence: 99%
“…Concerning applicability concerns, all articles showed an overall low level of concern, however, the domain “index test” showed more frequently an unclear concern because some papers did not sufficiently describe the scanning procedures and the used devices [ 40 , 46 , 55 ]. Regarding the quality assessment, the domain “patient selection” showed the highest risk of bias because of the exclusion of maxillofacial abnormalities [ 42 , 45 , 54 , 55 , 58 ] (this may result in overestimation of diagnostic accuracy [ 38 ]), the small number of participants [ 40 , 41 , 46 , 51 , 52 ] and the unclear method of random sampling [ 40 , 51 , 57 ]. Weighted bar chart for the risk of bias and application concerns of the selected studies is shown in Figure 2 .…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Recent research has indicated that the Bellus3D application compared well with more expensive devices for face scanning in terms of accuracy [ 22 , 23 , 24 , 25 ]. Although the Bellus3D application has been made unavailable for download since 1 December 2021, several other systems are currently available for 3D face scanning [ 22 , 23 , 24 , 25 ].…”
Section: Discussionmentioning
confidence: 99%
“…Subsequently, we determined that structured light scanning cameras using a proprietary camera, Bellus 3D™ camera (Bellus 3D, Campbell, CA) was very suitable. The accuracy of the Bellus camera is < 0.5 mm [ 23 ]. Later, we use either the iPhone X (Apple, Cupertino, CA) using built-in TrueDepth™ infrared camera and Bellus 3D Face App, or Heges 3D Scanner (Marek Šimoník, Opava, Czech Republic), an iPhone application.…”
Section: Methodsmentioning
confidence: 99%